2023
DOI: 10.1016/j.ultrasmedbio.2023.07.012
|View full text |Cite
|
Sign up to set email alerts
|

Flow Dynamics in Children With Bicuspid Aortic Valve: A Blood Speckle Tracking Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
0
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(19 citation statements)
references
References 48 publications
0
0
0
Order By: Relevance
“…Other studies [15,18] have proved how feasibility of BST for LV vortex analysis was also very high, varying from 95.6% to 98% [15,18] in healthy children to 93.7% for children with CHD [18]. BST, furthermore, was highly feasible in the evaluation and characterization of aortic flow patterns [8,19], as well as for the quantification of 2D of the left ventricle [15,18] and aortic [19] vortex dimensions. BST offered the advantage of accurate and reproducible quantification of complex and new parameters, such as vorticity [8] and energy loss [8,10], but only with dedicated research software [8,10].…”
Section: Feasibility In Different Conditionsmentioning
confidence: 97%
See 4 more Smart Citations
“…Other studies [15,18] have proved how feasibility of BST for LV vortex analysis was also very high, varying from 95.6% to 98% [15,18] in healthy children to 93.7% for children with CHD [18]. BST, furthermore, was highly feasible in the evaluation and characterization of aortic flow patterns [8,19], as well as for the quantification of 2D of the left ventricle [15,18] and aortic [19] vortex dimensions. BST offered the advantage of accurate and reproducible quantification of complex and new parameters, such as vorticity [8] and energy loss [8,10], but only with dedicated research software [8,10].…”
Section: Feasibility In Different Conditionsmentioning
confidence: 97%
“…BST, furthermore, was highly feasible in the evaluation and characterization of aortic flow patterns [8,19], as well as for the quantification of 2D of the left ventricle [15,18] and aortic [19] vortex dimensions. BST offered the advantage of accurate and reproducible quantification of complex and new parameters, such as vorticity [8] and energy loss [8,10], but only with dedicated research software [8,10]. Research software has recently employed (2023) [14] for BST evaluation of left ventricular intraventricular pressure difference (IVPD) in healthy children and in those with different cardiomyopathies with a good feasibility (e.g., feasibility of 88.3% in controls, 80% in children with dilated cardiomyopathy (DCM), and 90.4% in hypertrophic cardiomyopathy) [14].…”
Section: Feasibility In Different Conditionsmentioning
confidence: 99%
See 3 more Smart Citations