2017
DOI: 10.1016/j.watres.2017.01.065
|View full text |Cite
|
Sign up to set email alerts
|

Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking water monitoring

Abstract: Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, suppor… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
154
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 209 publications
(170 citation statements)
references
References 125 publications
5
154
0
Order By: Relevance
“…• What is the effect of UV irradiation on the nutrient availability and biostability 2 in spring water? Köster, & Egli, 2010;Van Nevel et al, 2017) also add significant value to this approach has yet to be evaluated. Irrespective of the applicability of currently emerging technologies, the general importance of microbiological online monitoring and automation (e.g., precipitation event-triggered automated sampling) is likely to increase in the near future (Besmer et al, 2016;Højris et al, 2016;Ryzinska-Paier et al, 2014;Stadler et al, 2016).…”
Section: Disinfectionmentioning
confidence: 99%
“…• What is the effect of UV irradiation on the nutrient availability and biostability 2 in spring water? Köster, & Egli, 2010;Van Nevel et al, 2017) also add significant value to this approach has yet to be evaluated. Irrespective of the applicability of currently emerging technologies, the general importance of microbiological online monitoring and automation (e.g., precipitation event-triggered automated sampling) is likely to increase in the near future (Besmer et al, 2016;Højris et al, 2016;Ryzinska-Paier et al, 2014;Stadler et al, 2016).…”
Section: Disinfectionmentioning
confidence: 99%
“…FCM has become the method of choice for quantifying microbial cells in aquatic samples, combining high sample throughput with speed and accuracy Van Nevel et al, 2017). Moreover, FCM has proved to be a useful tool not only for assessing cell abundance and viability but also for microbial community profiling Prest et al, 2014Prest et al, , 2013Ramseier et al, 2011).…”
Section: Introductionmentioning
confidence: 99%
“…fecal samples) and on coaggregated cells (biofilms/doublets/triplets). It was pointed out that several published dispersal protocols exist (see section 5.3 in for an overview). For example, predilution and sequential filtering over 30‐μm and 5‐μm filters is recommended for fecal material preparation (e.g.…”
Section: Discussionmentioning
confidence: 99%