1998
DOI: 10.1016/s0927-7757(96)03898-8
|View full text |Cite
|
Sign up to set email alerts
|

Floc size distribution in a membrane bioreactor and consequences for membrane fouling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
110
0
3

Year Published

2004
2004
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 275 publications
(118 citation statements)
references
References 11 publications
5
110
0
3
Order By: Relevance
“…Many studies have focused on the above problems [6,[13][14][15][16][17] and some procedures have been developed to reduce cake formation on the membrane surface. Conventional techniques for limiting membrane fouling are as follows:…”
Section: Membrane Foulingmentioning
confidence: 99%
See 1 more Smart Citation
“…Many studies have focused on the above problems [6,[13][14][15][16][17] and some procedures have been developed to reduce cake formation on the membrane surface. Conventional techniques for limiting membrane fouling are as follows:…”
Section: Membrane Foulingmentioning
confidence: 99%
“…Wisniewski and Grasmick [14] established the influence of the size distribution of a biological suspension on membrane fouling. They noted that the biological flocs are disintegrated by the (re)circulation inside the membrane bioreactor.…”
Section: Concentration and Sizes Of The Particles And The Flocsmentioning
confidence: 99%
“…La pompe à vis donne, dans des conditions de vitesses tangentielles et de pression identiques, de meilleures performances (jusqu'à 70 % supérieures). Cela pourrait s'expliquer par un cisaillement des particules constituant les MES, plus important avec la pompe à engrenages qu'avec la pompe à vis, ce qui conduirait à un colmatage en surface dû à un dépôt plus compact, (WISNIEWSKI et GRASMICK, 1998 ;VANDANJON étal., 1999).…”
Section: Incidence Du Type De Pompe Sur Les Performances De La Filtraunclassified
“…The composition and characteristics of the MBR suspension affect biofouling development and sludge cake deposition on the membrane surface (Brindle and Stephenson, 1996;Defrance et al, 2000;Hong et al, 2002;Lee et al, 2003). Half of the total fouling resistance is due to soluble compounds, especially biopolymers, in the MBR sludge (Wisniewski and Grasmick, 1998;Huang et al, 2000). In addition to soluble microbial products (SMPs), extracellular polymeric substances (EPSs) also play an important role in sludge cake accumulation on the membrane surface (Brindle and Stephenson, 1996;Chang and Lee, 1998;Cho and Fane, 2002;Rosenberger and Kraume, 2002).…”
Section: Introductionmentioning
confidence: 99%