Abstract: Nowadays, more and more lamp types are being used. Since different lamp types have different working principles, they also have different flicker responses. This paper shows the measurement results of different flicker responses for various types of lamps. These results prove that the UIE/IEC flickermeter, which has been used widely around the world for many years, cannot be used to advise on the flicker level of all lamp types. This is because of the fact that this flickermeter is based on a 230 V, 60 W or 12… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
16
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 46 publications
(16 citation statements)
references
References 7 publications
0
16
0
Order By: Relevance
“…According to (2), the flicker voltage source contains two frequency components in addition to the fundamental frequency f c : one is at a supersynchronous frequency that can be considered as an upper-sideband (USB with a frequency of f c + f m ) and another at a subsynchronous frequency that can be considered as a lower-sideband (LSB with a frequency f c − f m ). Such spectral components can generally exist as combinations of various frequency components that are superimposed on the fundamental frequency with same magnitude and contrary phase angles.…”
Section: Review Of Voltage Fluctuations and Flickermentioning
confidence: 99%
See 1 more Smart Citation
“…According to (2), the flicker voltage source contains two frequency components in addition to the fundamental frequency f c : one is at a supersynchronous frequency that can be considered as an upper-sideband (USB with a frequency of f c + f m ) and another at a subsynchronous frequency that can be considered as a lower-sideband (LSB with a frequency f c − f m ). Such spectral components can generally exist as combinations of various frequency components that are superimposed on the fundamental frequency with same magnitude and contrary phase angles.…”
Section: Review Of Voltage Fluctuations and Flickermentioning
confidence: 99%
“…These lamps are slowly being replaced by other, higher efficiency lamp types in the residential lighting market, such as compact fluorescent and other energy saving lamps. The literature [2] shows that the luminous output of these new lamp types has a reduced sensitivity to voltage fluctuations than the conventional incandescent lamp. This property is being used to support a discussion about a relaxation of the recommended or normative flicker index limits [3].…”
mentioning
confidence: 99%
“…With the traditional incandescent lamp being replaced by other, higher efficiency types which are less sensitive to voltage fluctuations suggests relaxation of voltage fluctuation limits and hence the flicker limits in power systems [1], [2]. However, the potential detrimental effects caused by increased voltage fluctuations on other electrical equipment should be considered before existing flicker limits are altered, where further detailed work should be undertaken, such as laboratory tests, considering voltage fluctuation levels greater than those which correspond to currently used flicker compatibility levels.…”
Section: Introductionmentioning
confidence: 99%
“…The processing performed by this system's signal chain is complicated [4] to such an extent that it is not easy to obtain output values only analytically. Bibliography concerning this subject contains numerous works that describe the operation and features of flickermeter [5][6][7][8][9][10]. In most of them, authors reconstruct flickermeter's characteristics for the case of amplitude modulation (AM) [3,11,12], input voltage with interharmonic component [12][13][14][15][16][17][18][19][20][21], or step changes of input voltage phase [12,[22][23][24][25].…”
Section: Introductionmentioning
confidence: 99%