2013
DOI: 10.1109/tie.2012.2185016
|View full text |Cite
|
Sign up to set email alerts
|

Flexible Voltage Support Control for Three-Phase Distributed Generation Inverters Under Grid Fault

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
200
0
1

Year Published

2014
2014
2020
2020

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 291 publications
(203 citation statements)
references
References 28 publications
2
200
0
1
Order By: Relevance
“…Focusing on the effects of voltage regulation in LV networks, other results are presented in [32]. Furthermore, the management of the local generators reactive power at positive and negative sequences allows, respectively, to control voltage amplitude and to balance phase voltages [33,34]. In [35], a parametrical analysis of voltage regulation through DGs reactive power injections has been carried out as a function of the network R/X ratio to maximize its effectiveness.…”
Section: Synthetic Inertiamentioning
confidence: 99%
“…Focusing on the effects of voltage regulation in LV networks, other results are presented in [32]. Furthermore, the management of the local generators reactive power at positive and negative sequences allows, respectively, to control voltage amplitude and to balance phase voltages [33,34]. In [35], a parametrical analysis of voltage regulation through DGs reactive power injections has been carried out as a function of the network R/X ratio to maximize its effectiveness.…”
Section: Synthetic Inertiamentioning
confidence: 99%
“…The fundamental components in the distorted voltage or current (dq theory) are DC quantities in these theories. MFI controllers based on instantaneous active and reactive power theory were studied in [30], [60], [71], [72], [77], [78], [81], [82], [99], [100], [106], [112], [114], [133], [137], [140], [153], [177], and [178], whereas synchronously rotating frame theory-based controllers were studied in [55]- [57], [63], [65], [66], [70], [80], [82], [85], [87]- [89], [101], [103], [104], [107], [118], [120], [129], [139], [148], [150], [151], [162], [165]- [167], [174], and [179]- [182]. Synchronously rotating frame theory has limitation...…”
Section: Classification Of Mfis Based On Control Techniquesmentioning
confidence: 99%
“…The PI-based DC-link voltage controller is simple to implement and is therefore preferred by most researchers, including [30], [32], [35], [38], [39], [55], [59], [60]- [62], [67], [75], [76], [79], [81], [92], [101]- [103], [107], [116]- [118], [120], [122]- [128], [130], [134], [136], [139], [140], [145], [146], [148], [155], [157], [160], [161], [165], [167], [171], and [184]- [186].…”
Section: Classification Of Mfis Based On Control Techniquesmentioning
confidence: 99%
“…In [17], a current reference calculation method is introduced to provide voltage support. Reference [18] aims at reducing active power oscillation to exploit the maximum capability of distributed generation.…”
Section: Introductionmentioning