2021
DOI: 10.1109/ojcas.2021.3122369
|View full text |Cite
|
Sign up to set email alerts
|

Flexible PCB Failures From Dynamic Activity and Their Impacts on Bioimpedance Measurements: A Wearable Case Study

Abstract: Wearable health monitoring systems that collect data in free-living environments are becoming increasingly popular. Flexible printed circuits provide a commercially available option that can conform to the shape of a wearable system and support electronic sensing and flexible interconnect. However, repetitive dynamic activity can stress and damage the interconnect of flexible PCBs which degrades data quality. This case study evaluated the performance of flexible PCBs providing interconnect between electrodes a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 47 publications
0
3
0
Order By: Relevance
“…In future prototypes, a Secure Digital (SD) memory card will be added to the Arduino board to prevent data loss in the event of a wireless communication failure. A bioimpedance measurement system using an SD card for data storage is described in [36] .…”
Section: Hardware Descriptionmentioning
confidence: 99%
“…In future prototypes, a Secure Digital (SD) memory card will be added to the Arduino board to prevent data loss in the event of a wireless communication failure. A bioimpedance measurement system using an SD card for data storage is described in [36] .…”
Section: Hardware Descriptionmentioning
confidence: 99%
“…For example, [ 36 ] includes a measurement test setup to characterize Lorentz-force MEMS magnetometers. On the other hand, [ 37 ] describes the difficulties of collecting data involving measurements with flexible printed circuit boards (PCBs) for wearable healthcare monitoring applications. As part of this research, a measurement platform was developed to experimentally investigate and demonstrate phenomena that enable magnetic modulation by exploiting the properties of micrometer-sized ME antennas.…”
Section: Introductionmentioning
confidence: 99%
“…Also, polyimide is attributed to excellent flexibility and high mechanical strength. On top of PI, copper wire and immersion gold can provide good electrical conductivity characteristics and chemical stability [17]. Furthermore, the FPCB has the potential to integrate with electronic circuits such as analog readout frontend and power management circuits for battery devices that can dramatically 2 MANUSCRIPT ID NUMBER reduce the device's size.…”
Section: Introductionmentioning
confidence: 99%