2016
DOI: 10.1016/j.snb.2015.09.030
|View full text |Cite
|
Sign up to set email alerts
|

Flexible 3D nitrogen-doped carbon nanotubes nanostructure: A good matrix for enzyme immobilization and biosensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
13
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 24 publications
(13 citation statements)
references
References 39 publications
0
13
0
Order By: Relevance
“…Glucose can be easily identified through amperometric monitor for the hydrogen peroxide released quantity. Zhang et al, have reported their study on the usage of flexible 3Dnitrogen-doped carbon nanotubes nanostructure as matrix for enzyme immobilization and biosensing[127]. In this work, an easy and scalable method for manufacturing a biosensor for detection of glucose was deevloped by glucose oxidase GOx immobilisation onto 3D N-doped CNTs support, based on electrospun carbon nanofibers film.…”
mentioning
confidence: 98%
See 1 more Smart Citation
“…Glucose can be easily identified through amperometric monitor for the hydrogen peroxide released quantity. Zhang et al, have reported their study on the usage of flexible 3Dnitrogen-doped carbon nanotubes nanostructure as matrix for enzyme immobilization and biosensing[127]. In this work, an easy and scalable method for manufacturing a biosensor for detection of glucose was deevloped by glucose oxidase GOx immobilisation onto 3D N-doped CNTs support, based on electrospun carbon nanofibers film.…”
mentioning
confidence: 98%
“…The biosensor has been found to exhibit very high reproducibility, good stability for enzime storage, anti-interferences high ability and high aplicability in real tests. Relatively simple preparation method as well as atractive analitical performances promotes this robust electrode for high performance electrochemical sensors development[127].…”
mentioning
confidence: 99%
“…7A). The as-prepared biosensor could reach the 95% , which was larger than that of GOD/ MWCNTs-chitosan (1.0-10.0 mM), 35 GOD-NCNT@CNFs (0.1-12.5 mM), 15 Naon-mesocellular graphene foam-GOD/GCE (1.0-12.0 mM) 36 , and ERGO-MWCNT/GOD/Nf electrode (0.01-6.5 mM). 37 Moreover, the detection of limit (LOD) was 5.0 mM (S/N ¼ 3), which was practicable for the determination of human blood sugar concentration (4.4-6.6 mM).…”
Section: Glucose Sensing Performance Of God/n-cnt@cfmentioning
confidence: 87%
“…Those results were similar to the previous report. 15 The control experiments indicated that T c ¼ 800 C was the best temperature among the three studied temperature. Therefore, in the following studies, T c ¼ 800 C was selected for synthesizing 3D N-CNT@CF hybrid.…”
Section: Characterizations Of N-cnt@cfmentioning
confidence: 93%
See 1 more Smart Citation