2000
DOI: 10.1054/arth.2000.4339
|View full text |Cite
|
Sign up to set email alerts
|

Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
138
1
4

Year Published

2001
2001
2018
2018

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 180 publications
(145 citation statements)
references
References 22 publications
2
138
1
4
Order By: Relevance
“…Numerous biomechanical studies investigated different techniques of periprosthetic fracture fixation [7][8][9][10][11][12], although as yet, not all types of these fractures or fixation methods have been comprehensively evaluated and new tools for fixation are on the way.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Numerous biomechanical studies investigated different techniques of periprosthetic fracture fixation [7][8][9][10][11][12], although as yet, not all types of these fractures or fixation methods have been comprehensively evaluated and new tools for fixation are on the way.…”
Section: Introductionmentioning
confidence: 99%
“…Various osteosynthetic devices have been developed over recent years to increase stability around the prosthesis [5,11,13]. New anatomically pre-shaped devices using angular stability may help to improve the outcome of those complicated fractures.…”
Section: Introductionmentioning
confidence: 99%
“…In a biomechanical study by Dennis et al (34), it was found that the system of plating with distal bicortical and proximal unicortical screws with or without a cable was biomechanically the most superior of the five systems studied.In another biomechanical study, Lever et al (35) compared the various fixation systems and found that the use of proximal unicortical and distal bicortical screws offered better stiffness and axial stability than use of cables in any instance.…”
Section: Discussionmentioning
confidence: 98%
“…Authors have reported good results after treatment of Type B1 fractures with lateral plates without bone grafting [1,5,20], whereas others advocate the routine use of cortical strut allografts with or without plates [6,12], especially in the presence of medial cortex comminution [8]. Biomechanical analyses investigating optimal construct stiffness have led to varying recommendations of ideal constructs including: nonlocking cable plate and allograft [23], allograft-plate [22], and plate with proximal unicortical screws with or without cables and distal bicortical screws [9].…”
Section: Discussionmentioning
confidence: 99%