Abstract: Although plates are the most stable means of fixation of midshaft metacarpal fractures, if minimally-invasive techniques are indicated, intramedullary nails may provide equivalent stability as commonly-used XK-wires. Although some studies have shown favorable clinical outcomes with IMNs, additional clinical correlation of these biomechanical results to fracture healing and outcomes is needed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

3
40
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 49 publications
(44 citation statements)
references
References 33 publications
(61 reference statements)
3
40
0
1
Order By: Relevance
“…However, no existent in vitro biomechanical test is able to reflect actual amounts of physiological loading. In addition to the cantilever bending test, previous studies have adopted tests including the three-point bending test [ 17 ], modified three-point bending test [ 13 , 21 , 22 ], four-point bending test [ 16 , 18 ], and torsional test [ 12 , 23 ]. We employed the cantilever bending test instead of a bending test mainly because the aim of the study was to explore fixation approaches for metacarpal neck fracture not metacarpal shaft fracture.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, no existent in vitro biomechanical test is able to reflect actual amounts of physiological loading. In addition to the cantilever bending test, previous studies have adopted tests including the three-point bending test [ 17 ], modified three-point bending test [ 13 , 21 , 22 ], four-point bending test [ 16 , 18 ], and torsional test [ 12 , 23 ]. We employed the cantilever bending test instead of a bending test mainly because the aim of the study was to explore fixation approaches for metacarpal neck fracture not metacarpal shaft fracture.…”
Section: Discussionmentioning
confidence: 99%
“…We employed the cantilever bending test instead of a bending test mainly because the aim of the study was to explore fixation approaches for metacarpal neck fracture not metacarpal shaft fracture. Previously, the maximum fracture force and stiffness were common indexes for scholars to determine fixation strength [ 12 , 14 , 16 , 17 , 21 , 23 ]. In this study, however, the strength was assessed by evaluating the stiffness alone.…”
Section: Discussionmentioning
confidence: 99%
“…20 Biomechanically, the fixation strength of intramedullary devices and multiple K-wire fixation are comparable. 21 Additional benefits to this technique include early mobilization (typically within 5 days) with subsequent rapid recovery of motion and function.…”
Section: Discussionmentioning
confidence: 99%
“…Despite the advantages, a strong consensus remains between investigators who conclude plate-screw fixation provides the most definitive type of stabilisation in metacarpal fractures in comparison to all other methods including intramedullary nailing 23 - 25 . This appears to be in concordance with findings by Curtis et al who performed a biomechanical comparative analysis between the intramedullary nail, crossed K-wire and plate screw constructs using composite bones 25 . Their data demonstrated that the average load to failure was significantly greater in plate-screw fixation compared to the other two techniques.…”
Section: Discussionmentioning
confidence: 99%