2012
DOI: 10.1016/j.ejmp.2011.07.002
|View full text |Cite
|
Sign up to set email alerts
|

Five-year experience of quality control for a 3D LSO-based whole-body PET scanner: Results and considerations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(13 citation statements)
references
References 11 publications
0
13
0
Order By: Relevance
“…In PET- and SPECT-based segmentation, an accurate standardization is needed, since SUV is dependent from different factors, like image acquisition and data reconstruction, VOI definition, tracer-specific pathophysiological factors, or the kinetics of tracer distribution. Even in single-center studies, SUV can show relevant variation over the years, as the detectors’ sensitivity dwindles [ 49 ]. Besides, the adoption of a fixed threshold does not in any way ensure a full specificity of the segmented uptake (as SUV of many benign processes overlaps with the metastases-related one) [ 50 ]; increasing this threshold might result in a loss of sensitivity while decreasing it might affect specificity.…”
Section: Resultsmentioning
confidence: 99%
“…In PET- and SPECT-based segmentation, an accurate standardization is needed, since SUV is dependent from different factors, like image acquisition and data reconstruction, VOI definition, tracer-specific pathophysiological factors, or the kinetics of tracer distribution. Even in single-center studies, SUV can show relevant variation over the years, as the detectors’ sensitivity dwindles [ 49 ]. Besides, the adoption of a fixed threshold does not in any way ensure a full specificity of the segmented uptake (as SUV of many benign processes overlaps with the metastases-related one) [ 50 ]; increasing this threshold might result in a loss of sensitivity while decreasing it might affect specificity.…”
Section: Resultsmentioning
confidence: 99%
“…For personal use only. jnm.snmjournals.org Downloaded from have to be individually established for the scanner used for imaging (27). By omitting any cut-off, our approach does not call for individual adaption and should be independent of scanner features.…”
Section: Early Termination Vs Completed 223ra Treatmentmentioning
confidence: 99%
“…The global FDD classification test Sensitivity was evaluated for the major faults. For the experiments, this is evaluated by dividing the number of correct channel statuses by the number of introduced faults: true positives positive conditions (1) The global FDD Specificity was evaluated as the number of correctly identified working channels divided by the number of properly working channels:…”
Section: B Global Diagnosis Statisticsmentioning
confidence: 99%