2021
DOI: 10.1117/1.ap.3.1.016002
|View full text |Cite
|
Sign up to set email alerts
|

Five-wavelength optical-resolution photoacoustic microscopy of blood and lymphatic vessels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
39
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
2

Relationship

3
6

Authors

Journals

citations
Cited by 62 publications
(46 citation statements)
references
References 51 publications
2
39
0
Order By: Relevance
“…1a). The laser consists of a nanosecond 532-nm pump laser (VPFL-G-20, Spectra-Physics) and a ber-based stimulated Raman scattering (SRS) shifter 19 . The pump laser operates at 4 kHz with 7-ns pulse width.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…1a). The laser consists of a nanosecond 532-nm pump laser (VPFL-G-20, Spectra-Physics) and a ber-based stimulated Raman scattering (SRS) shifter 19 . The pump laser operates at 4 kHz with 7-ns pulse width.…”
Section: Methodsmentioning
confidence: 99%
“…High detection sensitivity is not only important for high-quality imaging, but also enables the detection of more low-absorbing chromophores at a lower concentration, reduces photobleaching, toxicity, or perturbation, and allows for more choices of low-cost low-power lasers at a broader spectrum. For instance, in ophthalmologic examination 16 , low laser energy is preferred for more safety and comfort; in high-speed OR-PAM, increased pulse repetition rates (PRR) limits the laser pulse energy [17][18][19][20] ; wearable or portable OR-PAM prefers lightweight low-power lasers 21 ; long-term monitoring of pharmacokinetics or hemodynamics requires low-dose imaging to reduce photobleaching or phototoxicity.…”
Section: Introductionmentioning
confidence: 99%
“…At the output end of the fiber multiwavelength spectral peaks are generated through stimulated Raman scattering (SRS). SRS efficiency could be affected by temperature and airflow changes, and random errors and drift in pulse energy 24 . To improve the stability of the SRS peaks, the fiber was kept in a temperature-controlled unit to isolate the airflow and the temperature 25 .…”
Section: System Architecturementioning
confidence: 99%
“…As an emerging biomedical imaging technique, optical-resolution photoacoustic microscopy (OR-PAM) has a sub-cellular resolution, rich optical absorption contrasts, and label-free imaging ability [ [1] , [2] , [3] , [4] , [5] , [6] , [7] , [8] , [9] , [10] , [11] , [12] ]. Fast speed is of great importance for improving throughput and the study of physiological or pathological changes in vivo, such as brain activities, drug responses, and tumor metastasis processes, et al [ [13] , [14] , [15] , [16] , [17] ].…”
Section: Introductionmentioning
confidence: 99%