1994
DOI: 10.1063/1.1144880
|View full text |Cite
|
Sign up to set email alerts
|

First use of the UV Super-ACO free-electron laser: Fluorescence decays and rotational dynamics of the NADH coenzyme

Abstract: Significant improvements in the performances of the Super-ACO storage ring free-electron laser (FEL) at 800 MeV have been obtained recently: enhancement of the output power in the ultraviolet, laser duration of 10 h for the same injection of positrons, long-term stability with a micropulse of 60 ps FWHM. A first series of experiments using this FEL has then been successfully performed. Taking advantage of the time structure, the polarization and the high power of the source at 350 nm, the polarized fluorescenc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

15
90
0
2

Year Published

1995
1995
2015
2015

Publication Types

Select...
6
3

Relationship

2
7

Authors

Journals

citations
Cited by 82 publications
(107 citation statements)
references
References 29 publications
15
90
0
2
Order By: Relevance
“…We measure the total fluorescence decay to be bi-exponential with lifetimes (and amplitudes) 350 ps (0.77) and 760 ps (0.23) giving an average lifetime of 444 ps. The two lifetime components are comparable with those reported in literature and are believed to arise from the extended and folded populations respectively (12,21). The fluorescence anisotropy decay was found to be mono-exponential, with a rotational diffusion time of 290 ps and an initial anisotropy of 0.38 (Fig.…”
Section: Fig 2 Schematic Of the Measurement And Global Analysis Fitsupporting
confidence: 75%
See 1 more Smart Citation
“…We measure the total fluorescence decay to be bi-exponential with lifetimes (and amplitudes) 350 ps (0.77) and 760 ps (0.23) giving an average lifetime of 444 ps. The two lifetime components are comparable with those reported in literature and are believed to arise from the extended and folded populations respectively (12,21). The fluorescence anisotropy decay was found to be mono-exponential, with a rotational diffusion time of 290 ps and an initial anisotropy of 0.38 (Fig.…”
Section: Fig 2 Schematic Of the Measurement And Global Analysis Fitsupporting
confidence: 75%
“…This relation approximates the hydrodynamic volume (molecule ϩ hydrodynamic shell) of the molecule to be spherical, which is a reasonable approximation for NADH (21). We use this relation later to differentiate between free and bound NADH as well as to estimate the viscosity of the intracellular environment.…”
Section: Functional Form Of Fluorescence Anisotropy Decaymentioning
confidence: 99%
“…Après une expérience à un photon LEL de déclin de fluorescence polarisée en biologie [4], les applications se sont portées sur des expériences pompe/sonde à deux couleurs combinant le LEL et le Rayonnement Synchrotron (RS). Grâce à la synchronisation naturelle entre les deux sources, et à leur accordabilité, on peut effectuer des expériences résolues en temps et/ou en fréquence adaptées à l'études d'états excités et plus généralement de systèmes hors d'équilibre [5].…”
Section: Le Programme D'applicationunclassified
“…Des résultats originaux ont pu être obtenus, concernant l'équilibre thermodynamique entre les différents états conformationnels, et le volume hydrodynamique de l'état replié [19]. Les LELs sur anneaux de stockage sont particulièrement bien adaptés aux expériences pompe-sonde avec le rayonnement synchrotron, naturellement synchronisé avec le LEL.…”
Section: Applicationsunclassified