2019
DOI: 10.1063/1.5084696
|View full text |Cite
|
Sign up to set email alerts
|

First results using the new DLS Xspress4 digital pulse processor with monolithic segmented HPGe detectors on XAS beamlines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…Intensity of the incident beam (I 0 ) and the transmitted beam (I t ) were monitored by ionization chambers (filled with a mixture of He, N 2 , and Ar gases). Fluoresence measurements were performed using Canberra 36-pixel Monolithic Segmented Hyer Pure Germanium Dector (HPGe) partnered with the Xspress4 digital pulse processor 53 . For fluorescence measurements, M-N-C powdered samples were pressed into pellets (diameter: 8 mm), while for transmission measurements, standard reference samples were diluted with cellulose before pressing into pellets (diameter: 8 mm).…”
Section: Methodsmentioning
confidence: 99%
“…Intensity of the incident beam (I 0 ) and the transmitted beam (I t ) were monitored by ionization chambers (filled with a mixture of He, N 2 , and Ar gases). Fluoresence measurements were performed using Canberra 36-pixel Monolithic Segmented Hyer Pure Germanium Dector (HPGe) partnered with the Xspress4 digital pulse processor 53 . For fluorescence measurements, M-N-C powdered samples were pressed into pellets (diameter: 8 mm), while for transmission measurements, standard reference samples were diluted with cellulose before pressing into pellets (diameter: 8 mm).…”
Section: Methodsmentioning
confidence: 99%
“…The main specifications for the Digital Pulse Processor have been defined by the consortium early in the project, and after a review of existing commercialized systems, it was decided to purchase a 10-channel modified Xspress4 DPP developed by DIAMOND. One of the unique features of the Xspress4 is its ability to characterise and potentially correct for inter-pixel effects in segmented monolithic detectors [4].…”
Section: Electronic Chainmentioning
confidence: 99%
“…These events are removed in current commercial detectors using a collimator in front of the germanium sensor, at a cost of a significant reduction of the active area. Xspress4 DPP [12] will include a firmware option to reject charge sharing events, which is not available in recent commercial DPPs, like XIA-FalconX [13] or Xspress3M/X [14,15]. where C is the cadmium concentration in ppm (9150 ppm), N P ixels is the number of sensor elements (36 or 225), ICR P ixel is the pixel input count rate in counts per second (cps), DT is the DPP dead time in %, P/B is the Signal-to-Background ratio, P/T is the Signal-to-Total spectrum ratio and T exp is the exposure time in seconds (60 sec).…”
Section: Simulation Of the Performance Of A Multi-element Germanium D...mentioning