2015
DOI: 10.1016/j.physletb.2015.03.012
|View full text |Cite
|
Sign up to set email alerts
|

First results from the DarkSide-50 dark matter experiment at Laboratori Nazionali del Gran Sasso

Abstract: We report the first results of DarkSide-50, a direct search for dark matter operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a (46.4±0.7) kg active mass, operated inside a 30 t organic liquid scintillator neutron veto, which is in turn installed at the center of a 1 kt water Cherenkov veto for the residual flu… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

7
320
0
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 266 publications
(328 citation statements)
references
References 47 publications
7
320
0
1
Order By: Relevance
“…Therefore the smaller covariance of Slow/Total distribution certainly gives a stronger pulse shape discrimination (PSD) power. It should be noted that typical PSD covariance obtained by normal PMT+TPB method [8] is wider than that of the MPPC observed here, although direct comparisons would not be appropriate since detector condition and energy scale in addition to incident particles are all different. However, it is at least concluded that VUV MPPC should be very useful device for understanding argon scintillation process because of its direct detection capability and small covariance and also may potentially have a stronger PSD, applicable for dark matter search.…”
Section: Direct Detection Of Lar Scintillation Lightmentioning
confidence: 68%
“…Therefore the smaller covariance of Slow/Total distribution certainly gives a stronger pulse shape discrimination (PSD) power. It should be noted that typical PSD covariance obtained by normal PMT+TPB method [8] is wider than that of the MPPC observed here, although direct comparisons would not be appropriate since detector condition and energy scale in addition to incident particles are all different. However, it is at least concluded that VUV MPPC should be very useful device for understanding argon scintillation process because of its direct detection capability and small covariance and also may potentially have a stronger PSD, applicable for dark matter search.…”
Section: Direct Detection Of Lar Scintillation Lightmentioning
confidence: 68%
“…DarkSide-50k is a direct-detection dark matter search experiment, based on a Liquid Argon Time Projection Chamber (LAr-TPC) [1,2]. It is located at the Laboratorio Nazionale del Gran Sasso (LNGS) in Italy.…”
Section: What Is Darkside?mentioning
confidence: 99%
“…Electron-recoil background events (typically β /γ radiation) have S1 shape very different from that of NR (see Figure 1). The pulse shape discrimination (PSD) parameter f 90 -defined as the fraction of S1 signal detected in the first 90ns from the trigger -has been shown to discriminate between NR events and ER events at the level of 2 · 10 −7 [1]. …”
Section: Pulse Shape Discriminationmentioning
confidence: 99%
See 1 more Smart Citation
“…PMT has been an essential instrument for experimental particle physics, especially for the low background experiments such as DarkSide [1] and XENON [2], which are all expecting the least material near the target volume. The accuracy of SPE calibration of PMT is essential to energy reconstruction, which will directly affect the results of the experiment.…”
Section: Introductionmentioning
confidence: 99%