2019
DOI: 10.1088/1748-0221/14/09/c09037
|View full text |Cite
|
Sign up to set email alerts
|

First results from an event synchronized—high repetition Thomson scattering system at Wendelstein 7-X

Abstract: Contents 1 Introduction 1 2 Increasing the laser repetition rate 2 3 Realization of the event synchronization 4 4 A possible application: cryogenic H 2 pellet injection 6

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 18 publications
(18 reference statements)
0
2
0
Order By: Relevance
“…Two observation optics cover a total of presently 42 volumes on the inboard-and outboard side of the plasma by means of 20 polychromators with 5 spectral channels each. An event-synchronized 18 pulse "burst" sequence within an ∼1.5 ms short interval with full laser energy but repetition then reduced to 5 Hz can be realized for fast events such as the density evolution after pellet injection [25]. In preparation of long-pulse operation an automated laser beam position control is presently implemented to cope with geometrical drifts of the necessary long pathways of more than 30 m.…”
Section: Core Profile Diagnosticsmentioning
confidence: 99%
“…Two observation optics cover a total of presently 42 volumes on the inboard-and outboard side of the plasma by means of 20 polychromators with 5 spectral channels each. An event-synchronized 18 pulse "burst" sequence within an ∼1.5 ms short interval with full laser energy but repetition then reduced to 5 Hz can be realized for fast events such as the density evolution after pellet injection [25]. In preparation of long-pulse operation an automated laser beam position control is presently implemented to cope with geometrical drifts of the necessary long pathways of more than 30 m.…”
Section: Core Profile Diagnosticsmentioning
confidence: 99%
“…For a pellet-injected plasma, two of them were pulsed with a short interval of 200 s 20 . For the same purpose, Thomson scattering diagnostic systems with high-repetition-rate lasers have been developed in W7-X with 12 burst pulses on a 5 Hz basis 21 . Profiles of and were obtained with a time interval of 100 s during the injection process of a cryogenic pellet.…”
Section: Introductionmentioning