2003
DOI: 10.1016/s0168-583x(02)02108-0
|View full text |Cite
|
Sign up to set email alerts
|

First radioactive ions charge bred in REXEBIS at the REX-ISOLDE accelerator

Abstract: Johannes Gutenberg-U ni v ersi tä t M ai nz , Germ any J . C e d e r k ä ll, O . F or s t ne r , F . We na nd e r , C E R N , S w i tz erl and R E X T R A P , a n d t h e r e a ft e r i n j e c t e d i n t o t h e E B I S w i t h a n e n e r g y u p t o 6 0 k e V .T h e R E X E B I S p r o d u c e d t h e fi r s t c h a r g e b r e d i o n s i n A u g u s t 2 0 0 1 a n d h a s b e e n r u n n i n g n e a r l y n o n -s t o p b e a m s g e n e r a t e d i n t h e t e s ti o n -s o u r c e i n fr o n t o f R E X… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0

Year Published

2004
2004
2015
2015

Publication Types

Select...
7
3

Relationship

2
8

Authors

Journals

citations
Cited by 31 publications
(18 citation statements)
references
References 5 publications
0
18
0
Order By: Relevance
“…Element-selective ionisation takes place with the Resonance Laser Ionisation Laser Ion Source (RILIS) [14,36,37] and the Mn 1+ ions are extracted from the ion source with a 30 kV potential and mass separated with the General Purpose Separator (GPS). After this the beam is bunched in REX-TRAP [38,39] and released into the charge breeder, REX-EBIS [38,39], finally attaining a charge state of 21 + . The latter stage is required in order to achieve a mass to charge ratio of A/q < 4.5 for injection to the REX linear accelerator [40].…”
Section: Methodsmentioning
confidence: 99%
“…Element-selective ionisation takes place with the Resonance Laser Ionisation Laser Ion Source (RILIS) [14,36,37] and the Mn 1+ ions are extracted from the ion source with a 30 kV potential and mass separated with the General Purpose Separator (GPS). After this the beam is bunched in REX-TRAP [38,39] and released into the charge breeder, REX-EBIS [38,39], finally attaining a charge state of 21 + . The latter stage is required in order to achieve a mass to charge ratio of A/q < 4.5 for injection to the REX linear accelerator [40].…”
Section: Methodsmentioning
confidence: 99%
“…The cooling in REX-TRAP is mass dependent and potentially some additional mass selectivity can be achieved in REXTRAP, in order to purify the radioactive beam from stable isobaric contaminants [52]. Secondly, the accumulated and cooled isotopes are transmitted to the REX Electron Beam Ion Source (REXEBIS) [53][54][55] in a short time period of some 10 μs. The isotopes spend the same period in the REXE-BIS charge breeder.…”
Section: Specific Timing At Isoldementioning
confidence: 99%
“…The best attained efficiency result for the REXEBIS (including beam transport from trap to EBIS, EBIS injection-breeding-extraction, and a mass separator efficiency of 80%) is >10% for potassium breeding. The average efficiency over the whole range Li to Cs is between 5 and 10% [17], and for higher intensities the efficiency can drop to as low as 2%. To this value the trap efficiency of ~40% should be included.…”
Section: Breeding Efficiencymentioning
confidence: 98%