2021
DOI: 10.1007/s12194-021-00645-z
|View full text |Cite
|
Sign up to set email alerts
|

First optical observation of 10B-neutron capture reactions using a boron-added liquid scintillator for quality assurance in boron neutron capture therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 11 publications
0
7
0
Order By: Relevance
“…The camera system used was the same as that used in our previous paper 14 : a cooled CCD camera (SBIG-8300 M, SBIG, California, USA) with a 16-bit monochrome image sensor and an optical lens with an fnumber of 0.95 (Xenon25 F/0.95, Schneider, Germany). The camera was cooled to −5 • C during the experiment to suppress dark current noise and operated in a pixel binning mode of 5 × 5, such that the resolution of the images was 670 × 506 pixels.…”
Section: Phantom Preparation and Camera Systemmentioning
confidence: 99%
See 3 more Smart Citations
“…The camera system used was the same as that used in our previous paper 14 : a cooled CCD camera (SBIG-8300 M, SBIG, California, USA) with a 16-bit monochrome image sensor and an optical lens with an fnumber of 0.95 (Xenon25 F/0.95, Schneider, Germany). The camera was cooled to −5 • C during the experiment to suppress dark current noise and operated in a pixel binning mode of 5 × 5, such that the resolution of the images was 670 × 506 pixels.…”
Section: Phantom Preparation and Camera Systemmentioning
confidence: 99%
“…In contrast, in our preliminary experiments at the E-3 port of KUR, the luminescence of the 0 wt% phantom was less than 2 % of that of the 1 wt% phantom. 14 We assumed that the major origin of the present high background luminescence might be the presence of water around the phantom. Owing to 1 H(n, γ) 2 H reaction, 2.2 MeV gamma rays with a long mean free path are generated.…”
Section: Background Luminescence Of the 0 Wt% Phantommentioning
confidence: 99%
See 2 more Smart Citations
“…The final-selection committee, comprising the Editor-in-Chief and seven Deputy Editors, then made the final decisions. On behalf of the Editorial Board, the Editor-in-Chief nominated three first authors of the best original papers [1][2][3]: Takayuki Okamoto for Medical Imaging, Yuma Iwao for Nuclear Medicine and Magnetic Resonance Imaging, and Akihiro Nohtomi for Radiation Therapy to the awarding societies.…”
mentioning
confidence: 99%