2004
DOI: 10.1016/s0925-8388(03)00585-1
|View full text |Cite
|
Sign up to set email alerts
|

First experiments at the Swiss Light Source Materials Science beamline powder diffractometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
47
0

Year Published

2006
2006
2017
2017

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 42 publications
(48 citation statements)
references
References 13 publications
1
47
0
Order By: Relevance
“…5(b), note the good agreement for the superlattice reflections. By using the FINDSYM program [19], the symmetry of the refined modulated structure was determined to be C2/m, with a = 10.357 35 (15), b = 7.195 62 (11), c = 10.454 72 (5), and β = 90.0206 (11) • . In the modulated structure, the octahedral Mn(B) site splits into one Mn 4+ site with an 8j general position and two Mn 3+ sites (4e-4f ).…”
Section: Mn-b2 Mn-a'mentioning
confidence: 99%
“…5(b), note the good agreement for the superlattice reflections. By using the FINDSYM program [19], the symmetry of the refined modulated structure was determined to be C2/m, with a = 10.357 35 (15), b = 7.195 62 (11), c = 10.454 72 (5), and β = 90.0206 (11) • . In the modulated structure, the octahedral Mn(B) site splits into one Mn 4+ site with an 8j general position and two Mn 3+ sites (4e-4f ).…”
Section: Mn-b2 Mn-a'mentioning
confidence: 99%
“…aberration-free optics such as those available at the SLS-MS beamline [4][5][6]. Under these conditions the profile broadening due to the optics can be considered purely Gaussian [4]; optimal calibration of the diffractometer and the detector [1]; negligible absorption effects.…”
Section: Aberrations In Debye-scherrer Geometrymentioning
confidence: 99%
“…All these aberrations are here analytically modelled for the case of a virtually aberration-free optics and fully parallel beam, as the Materials Science (MS) beamline at the SLS [4][5][6] can provide. The resulting expressions can be seamlessly incorporated in any data analysis program so as to be fully taken into account.…”
Section: Introductionmentioning
confidence: 99%
“…KeV and a size of 400 × 200 µm 2 is selected and the diffraction patterns are recorded with the MYTHEN II microstrip detector [17]. The diffraction peaks are fitted with a split Pearson-VII function plus a linear function (for background noise) and information about full-width-at half-maximum (FWHM), integral width (iw) and peak position (θ) are extracted.…”
Section: In-situ Tensile Testingmentioning
confidence: 99%