2022
DOI: 10.1007/s00062-022-01237-z
|View full text |Cite
|
Sign up to set email alerts
|

First Experience with the Nimbus Stentretriever

Abstract: Purpose To share our first experience with the Nimbus stentretriever, a multizone device designed to assist neurointerventionalists in handling fibrin-rich clots in endovascular stroke treatment. Methods We retrospectively analyzed the data of patients who were treated with the Nimbus stentretriever at our high-volume stroke center between May 2021 and May 2022. We evaluated the number of passes before Nimbus was used, the number of passes with nimbus, as … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 25 publications
0
2
1
Order By: Relevance
“…To retrieve such hard clot, special measures such as the Nimbus stent retriever (Cerenovus, Johnson & Johnson, New Brunswick, NJ) could be used to remove the fibrin-rich clots. 25 In patients with LIC, there was no difference in mRS score 0 to 3 at 90 days between patients who achieved mTICI score 2c/3 and 2b in this study. It suggested that patients with LIC had a smaller residual functional parenchyma than those without, and therefore, even if an mTICI score of 2c/3 was not achieved, it could be sufficient to achieve an mTICI score of 2b, including artery that supplied the residual function territory.…”
Section: Discussioncontrasting
confidence: 52%
See 1 more Smart Citation
“…To retrieve such hard clot, special measures such as the Nimbus stent retriever (Cerenovus, Johnson & Johnson, New Brunswick, NJ) could be used to remove the fibrin-rich clots. 25 In patients with LIC, there was no difference in mRS score 0 to 3 at 90 days between patients who achieved mTICI score 2c/3 and 2b in this study. It suggested that patients with LIC had a smaller residual functional parenchyma than those without, and therefore, even if an mTICI score of 2c/3 was not achieved, it could be sufficient to achieve an mTICI score of 2b, including artery that supplied the residual function territory.…”
Section: Discussioncontrasting
confidence: 52%
“…To retrieve such hard clot, special measures such as the Nimbus stent retriever (Cerenovus, Johnson & Johnson, New Brunswick, NJ) could be used to remove the fibrin-rich clots. 25…”
Section: Discussionmentioning
confidence: 99%
“…When it is impossible to reach the occlusion with the aspiration catheter, only a stent retriever technique is used [13]. The third, and all further attempts, usually involve a different ("rescue") method ("rescue"), either by combining a stent for direct aspiration only or by changing the type of stent [14,15] or the aspiration catheter used [16,17] (Figure 1). combining a stent for direct aspiration only or by changing the type of stent [14,15] or the aspiration catheter used [16,17] (Figure 1).…”
Section: Populationmentioning
confidence: 99%