2022
DOI: 10.1007/s10840-022-01329-3
|View full text |Cite
|
Sign up to set email alerts
|

First experience with a transseptal puncture using a novel transseptal crossing device with integrated dilator and needle

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 15 publications
0
9
0
Order By: Relevance
“…So far, a few experiences with the AcQCross[?] Qx system have been published 1,6,7 , which documented safety and improved procedural efficacy, as the time needed for TSP was significantly lower in AcQCross Qx groups as compared to traditional TSP approach. The main novelty of our approach consists in TSP monitoring.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…So far, a few experiences with the AcQCross[?] Qx system have been published 1,6,7 , which documented safety and improved procedural efficacy, as the time needed for TSP was significantly lower in AcQCross Qx groups as compared to traditional TSP approach. The main novelty of our approach consists in TSP monitoring.…”
Section: Discussionmentioning
confidence: 99%
“…The main novelty of our approach consists in TSP monitoring. While Rizzi et al 1 and Yap et al 6,7 performed TSP respectively under transesophageal echocardiography monitoring the former and intracardiac imaging the latter, we chose to safely perform TSP with AcQCross[?] Qx system under fluoroscopy monitoring.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…CBA technique has evolved over the years with some modifications to optimize the procedural workflow: single‐freeze strategy (eliminating a bonus freeze), shorter freezing application (180 vs. 240 s), time‐to‐isolation‐guided ablation, shorter distal tip, fluoroscopy exposure reduction, and the use of a figure‐of‐8 suture 3–5 . In this sense, the AcQCross system (Medtronic), a novel integrated dilator‐needle system, was recently introduced to reduce the number of exchanges for a transseptal access (TSA) 6 . In CBA procedures, left atrium (LA) access is generally achieved using a standard sheath that is exchanged for the 12F cryoballoon delivery sheath and dilator over a long wire.…”
Section: Introductionmentioning
confidence: 99%
“…Yet, they all require significant alteration of the conventional TSP kit (Figure 1). One example is the "all-in-one" integrated transseptal crossing device for TSP developed by Rizzi et al [11]. Other examples include a radiofrequency needle for TSP [12], and a transseptal approach using a non-fluoroscopic technique [13], [14].…”
Section: Introductionmentioning
confidence: 99%