2008
DOI: 10.1016/j.electacta.2008.04.082
|View full text |Cite
|
Sign up to set email alerts
|

First evaluation of the applicability of microbial extracellular polymeric substances for corrosion protection of metal substrates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
44
0
3

Year Published

2010
2010
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 70 publications
(50 citation statements)
references
References 38 publications
1
44
0
3
Order By: Relevance
“…Finally, recent studies showed that using the EPS, separated from the microbes, could reduce corrosion by SRB (Stadler et al, 2008(Stadler et al, , 2010Finkenstadt et al, 2011). This corrosion protection by EPS appeared to be species dependent.…”
Section: Metal Corrosion Inhibition Using Microbially Based Techniquesmentioning
confidence: 99%
“…Finally, recent studies showed that using the EPS, separated from the microbes, could reduce corrosion by SRB (Stadler et al, 2008(Stadler et al, , 2010Finkenstadt et al, 2011). This corrosion protection by EPS appeared to be species dependent.…”
Section: Metal Corrosion Inhibition Using Microbially Based Techniquesmentioning
confidence: 99%
“…Bakterije kolonizuju površinu metala i proizvode heterogene ekstracelularne polimerne supstance koje prijanjanju za metalnu površinu zbog prisustva funkcionalnih grupa u molekulima EPS. Utvrđeno je da dekstrani koji ulaze u sastav EPS imaju sposobnost inhibiranja korozije metala [28].…”
Section: Formiranje Biofilmaunclassified
“…Utvrđeno je da EPS mogu inhibirati aktivnost sulfat-redukujućih bakterija (SRB) [28,32,33]. Tako bakterijska vrsta Desulfovibrio alaskensis sintetiše EPS koji inhibiraju koroziju gvožđa i ugljeničnog čelika, dok vrste Desulfovibrio vulgaris i Desulfovibrio indonesiensis svojom metaboličkom aktivnošću sintetišu EPS koji se ponašaju kao aktivatori korozionih procesa [28].…”
Section: Inhibicija Korozije Pomoću Biofilmaunclassified
“…The stopper/wire system was then fitted to serum bottles with sterile medium and purged with N 2 . Stadler and others (2008) 13 Pure iron (Armco), carbon steel ST37, stainless steel AISI 304 (UNS S30400) Coupons in Teflon holders were placed in a glass beaker, covered with aluminum foil and sterilized by heat-treatment for 9 hours at 130 • C. Further work requiring sterile conditions was performed in a clean bench. Stranger-Johannessen (1987) 74 Painted steel plates…”
Section: Methodsmentioning
confidence: 99%
“…• C in glass beakers covered with aluminum foil; 13 or the use of ultraviolet light. 14 It is important to mention that the methods listed in Table I correspond roughly to the same number of papers explicitly describing the sterilization procedures in the methodology section of the manuscript.…”
mentioning
confidence: 99%