2022
DOI: 10.1177/1420326x211073130
|View full text |Cite
|
Sign up to set email alerts
|

Fire safety of building integrated photovoltaic systems: Critical review for codes and standards

Abstract: A critical review of current regulations and standards is presented pertaining to the fire safety of the integration of photovoltaic (PV) systems into buildings. Building integrated photovoltaic (BIPV) systems need to meet both fire safety requirements as PV systems as well as the building fire codes requirements as building structural components (e.g. facades, roofing and glazing). However, the current building codes do not provide provisions that cover various applications of BIPV. Furthermore, the new build… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2
1
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…Currently, there are no BIPV specific rules, regulations, and policies in most countries [8]. BIPV must comply with building codes as well as the electrical codes with assured structural strength and fire safety [18,19]. Since these rules are not clearly defined for BIPV projects, confusions may happen which could limit the trust and confidence of the building and PV stakeholders.…”
Section: Lack Of Stakeholder Trustmentioning
confidence: 99%
“…Currently, there are no BIPV specific rules, regulations, and policies in most countries [8]. BIPV must comply with building codes as well as the electrical codes with assured structural strength and fire safety [18,19]. Since these rules are not clearly defined for BIPV projects, confusions may happen which could limit the trust and confidence of the building and PV stakeholders.…”
Section: Lack Of Stakeholder Trustmentioning
confidence: 99%
“…In another subsequent study, Kristensen et al [21] proposed a critical gap height for different modules sizes that could reduce the fire risk associated with PVMs on flat roofs. Consequently, some authors developed critical analyzes of various studies in state of the art on the topics of photovoltaic systems in buildings, such as fire safety and mitigation strategies, best PV installation practices, current regulations and standards, and even safety practices for firefighters during photovoltaic fires [22][23][24][25][26].…”
Section: Introductionmentioning
confidence: 99%