2012
DOI: 10.1016/j.jbiomech.2012.07.021
|View full text |Cite
|
Sign up to set email alerts
|

Finite element modelling of stapled colorectal end-to-end anastomosis: Advantages of variable height stapler design

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(19 citation statements)
references
References 33 publications
0
18
0
1
Order By: Relevance
“…By providing varied staple heights within the same firing, there is reportedly less stress on the tissue along the outer staple line. 51,52 Ethicon-Endo Surgery, Inc. (Cincinnati, OH) has recently introduced the EES Linear Cutter™, which employs a novel 3D staple using a single cartridge containing 3 different staple heights, enabling the surgeon to select staple height without switching cartridges. A literature search of this method produced a single study that reported that the stapler was as safe as a standard linear cutter and produced less bleeding along the anastomosis in people.…”
Section: Discussionmentioning
confidence: 99%
“…By providing varied staple heights within the same firing, there is reportedly less stress on the tissue along the outer staple line. 51,52 Ethicon-Endo Surgery, Inc. (Cincinnati, OH) has recently introduced the EES Linear Cutter™, which employs a novel 3D staple using a single cartridge containing 3 different staple heights, enabling the surgeon to select staple height without switching cartridges. A literature search of this method produced a single study that reported that the stapler was as safe as a standard linear cutter and produced less bleeding along the anastomosis in people.…”
Section: Discussionmentioning
confidence: 99%
“…; Nováček et al . ). The development of such computational models requires the definition of constitutive formulations of the biological tissues (Maurel et al .…”
Section: Introductionmentioning
confidence: 97%
“…Many techniques have been provided for colon screening and surgery, aiming at the less invasive action . The design of surgical procedures and devices, together with prosthetic elements and biomaterials, is correlated with the analysis of the tissues and the organs functionality from a biomechanical point of view . Numerical models can be used to interpret the actual configuration and mechanical behavior of colon structures and tissues .…”
Section: Introductionmentioning
confidence: 99%