2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena 2011
DOI: 10.1109/ceidp.2011.6232629
|View full text |Cite
|
Sign up to set email alerts
|

Finite element modeling and analysis of human breast tissue for electrochemotherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2014
2014
2018
2018

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 7 publications
0
2
0
Order By: Relevance
“…21 In the last years, new designs of larger electrodes, including arrays of parallel needles or composition of triangular configurations, mounted on rigid support and used to cover larger surfaces, have been presented. [22][23][24] A different approach has been proposed in the grid electrode: the design of a prototype of grid electrode including a solution for its connection to a voltage pulse generator and the evaluation of its electroporation efficiency in a cellular model has been reported in 21. With this solution detailed in the previous study, 21 an area of some tens of cm 2 can be treated by means of a grid of equispaced needle electrodes suitably supplied in order to limit the treatment time.…”
Section: Introductionmentioning
confidence: 99%
“…21 In the last years, new designs of larger electrodes, including arrays of parallel needles or composition of triangular configurations, mounted on rigid support and used to cover larger surfaces, have been presented. [22][23][24] A different approach has been proposed in the grid electrode: the design of a prototype of grid electrode including a solution for its connection to a voltage pulse generator and the evaluation of its electroporation efficiency in a cellular model has been reported in 21. With this solution detailed in the previous study, 21 an area of some tens of cm 2 can be treated by means of a grid of equispaced needle electrodes suitably supplied in order to limit the treatment time.…”
Section: Introductionmentioning
confidence: 99%
“…One possible strategy is represented by the development of large surface electrodes arrangement suitable for the application on wide areas. A possible strategy was proposed in the studies of Agoramurthy et al [28] and of Bommakanti et al [29], in which the idea of larger electrodes with respect to the standard one has been explored by means of simulations tools in order to evaluate the electric field distribution. In this case the proposed device is based on linear arrays of needles.…”
Section: Introductionmentioning
confidence: 99%