Finite element model based on a mandibular cast and a waxed complete denture: Evaluation of the accuracy and the reproducibility of analysis

Abstract: We conclude that this method has sufficient measurement accuracy and reproducibility for the calculated movement of dentures.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…Other studies have adopted either fully bonded, fully tied or other linear contact mechanism between the denture and the mucosa, to simulate a linear transmission of occlusal forces [ 78 , 83 , 86 , 87 , 92 , 99 , 100 , 102 , 106 ]. On the other hand, while incorporating this nonlinear mechanism, most studies adopted different frictional coefficients ranging from 0 (frictionless) to 0.75 (penalty contact) [ 76 , 77 , 84 , 85 , 88 , 90 , 91 , 93 , 97 , 101 , 147 , 178 , 180 , 185 ].…”
Section: Biomechanical Responsesmentioning
confidence: 99%
See 1 more Smart Citation
“…Other studies have adopted either fully bonded, fully tied or other linear contact mechanism between the denture and the mucosa, to simulate a linear transmission of occlusal forces [ 78 , 83 , 86 , 87 , 92 , 99 , 100 , 102 , 106 ]. On the other hand, while incorporating this nonlinear mechanism, most studies adopted different frictional coefficients ranging from 0 (frictionless) to 0.75 (penalty contact) [ 76 , 77 , 84 , 85 , 88 , 90 , 91 , 93 , 97 , 101 , 147 , 178 , 180 , 185 ].…”
Section: Biomechanical Responsesmentioning
confidence: 99%
“…Interface 12: 20150325 forces [78,83,86,87,92,99,100,102,106]. On the other hand, while incorporating this nonlinear mechanism, most studies adopted different frictional coefficients ranging from 0 (frictionless) to 0.75 ( penalty contact) [76,77,84,85,88,90,91,93,97,101,147,178,180,185].…”
Section: Friction Coefficientmentioning
confidence: 99%
“…The techniques for acquiring geometrical data include manual tracing, computed tomography (CT) scanning, and magnetic resonance imaging (MRI); the collected information is then input into a computer-aided design (CAD) program, from which meshable data can be exported. Touch-probe digitizers [6] and laser scanners [7] can provide highly accurate measurements of the surface, while CT [8] and MRI [9] can elucidate the internal structures and material properties. These methods have been used in combination for the simulation of a set of vertebrae or segments of the human spine [7].…”
Section: Introductionmentioning
confidence: 99%
“…Computer‐aided design and manufacturing (CAD/CAM) of removable prostheses have been performed since the 1990s. Although digitalized construction and duplication procedure of complete dentures (36–38), knowledge‐based systems (39, 40), digitalized casts and surveying system (41), rapid prototyping system (42) for designing and construction of RPDs have been reported, a total CAD/CAM system for removable prostheses is yet to be developed. To utilize CAD/CAM in this field, we have to make an easy‐to‐handle system in which the process of traditional dental laboratory technique as well as rational design concepts can be digitalized on the computer.…”
Section: Introductionmentioning
confidence: 99%