Finite Control Set Model Predictive Control of Static Compensator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
2
2
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…Additionally, the CHB-based MMC design avoids the need to incorporate an extensive array of flying capacitors or clamping diodes in the power converter topology [17]. Consequently, one of the most widely discussed topologies in the literature is the seven-level voltage source converter (7L-VSC) based on three CHB cells in series per phase [18]. However, both 2L-VSC and 7L-VSC topologies are based on AC-DC-AC configurations, which require the inclusion of an intermediate stage of energy storage elements such as capacitor banks.…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, the CHB-based MMC design avoids the need to incorporate an extensive array of flying capacitors or clamping diodes in the power converter topology [17]. Consequently, one of the most widely discussed topologies in the literature is the seven-level voltage source converter (7L-VSC) based on three CHB cells in series per phase [18]. However, both 2L-VSC and 7L-VSC topologies are based on AC-DC-AC configurations, which require the inclusion of an intermediate stage of energy storage elements such as capacitor banks.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the MMC does not demand a vast number of flying capacitors or clamping diodes [12]. Consequently, the CHB-based MMC is currently a competitive choice in the new era of VSCs [13].…”
Section: Introductionmentioning
confidence: 99%
“…These algorithms need a large number of measured signals which are necessary for computing of proper control steps [1]. For example, in case of STATCOM application these algorithms must ensure balancing of dc-link capacitors voltages and generating of suitable current waveform into the power grid [2], [9]. For optimal function of the control algorithm, all dc-link voltages, all compensation currents, all grid voltages and all grid currents have to be measured.…”
Section: Introductionmentioning
confidence: 99%