2021
DOI: 10.1109/tec.2021.3063601
|View full text |Cite
|
Sign up to set email alerts
|

Finite Control Set – Model Predictive Control Based On Sliding Mode For Bidirectional Power Inverter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
7
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 18 publications
(7 citation statements)
references
References 45 publications
0
7
0
Order By: Relevance
“…Figure 15 shows the bidirectional inverter used as a gateway between the NG and the AC mains. The detailed model of the bidirectional inverter can be found in [16]. The difference equations associated with this converter are:…”
Section: Power Converter Modelsmentioning
confidence: 99%
See 1 more Smart Citation
“…Figure 15 shows the bidirectional inverter used as a gateway between the NG and the AC mains. The detailed model of the bidirectional inverter can be found in [16]. The difference equations associated with this converter are:…”
Section: Power Converter Modelsmentioning
confidence: 99%
“…Figure19shows the implementation of the BI model, the generation of the three-phase power supply signals, and the control used for this converter based on[16].…”
mentioning
confidence: 99%
“…There are two types of HIL the controller hardware in the loop (CHIL) and the power hardware in the loop (PHIL). In CHIL the objective is to test the controller, in Mitsugi et al (2020) it is used to test the control of an energy storage system, in Amiri et al (2020), it is used to test the controller of a converter used to correct the power factor, in Zucuni et al (2020), and (Estrada et al, 2021), it is used to test a new cost function for predictive controllers, in Busarello et al (2020) it is used to test digital controls for converters connected to the electrical network, the HIL simulation is helpful to reduce the time to market for new products.…”
Section: Introductionmentioning
confidence: 99%
“…Although the robustness is improved, it is essentially a multi-loop control instead of single-loop multi-variable control, which may increase the implementation complexity. In [26], [27], the reaching conditions of continuous-time SMC are included in the cost function of FS-MPC to guarantee the stability. Nevertheless, the control objective is to find the most negative value of the cost function instead of minimizing the tracking errors, which may degrade the steady-state performance.…”
Section: Introductionmentioning
confidence: 99%