2022
DOI: 10.1016/j.engstruct.2022.114137
|View full text |Cite
|
Sign up to set email alerts
|

Finite contact duration modeling of a Vibro-Impact Nonlinear Energy Sink to protect a civil engineering frame structure against seismic events

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 69 publications
0
7
0
Order By: Relevance
“…However, the phase point will eventually jump and be captured again by the SIM and this will cause intervals of 1:1 oscillations with random amplitude and length [99,100]. In [234], two viscoelastic dissipative contact models were implemented in the NES which included instantaneous and finite contact (Tsuji [235] and Kuwabara [236]) models. The resulting NES is similar to the one employed in [95,97,101].…”
Section: Analytical Treatmentmentioning
confidence: 99%
“…However, the phase point will eventually jump and be captured again by the SIM and this will cause intervals of 1:1 oscillations with random amplitude and length [99,100]. In [234], two viscoelastic dissipative contact models were implemented in the NES which included instantaneous and finite contact (Tsuji [235] and Kuwabara [236]) models. The resulting NES is similar to the one employed in [95,97,101].…”
Section: Analytical Treatmentmentioning
confidence: 99%
“…In [1], the authors claim that the performance of the enhanced SSVIe NES of nearly 0.45 coefficient of restitution is found to be more robust to the initial impulsive energy levels and to its physical parameters variation. However, in [22], the authors study the VI NES with a finite contact duration model. They use Hertz model of finite duration collision and compare it with two other models.…”
Section: An Impact Occurs Whenmentioning
confidence: 99%
“…It is assumed that the number of impulse repetitions is so large that the structure oscillations are steady state. In [22], the authors choose the well-known El Centro NS signal (1940) as the primary seismic excitation (Fig. 10).…”
Section: A Shock In the Half-sine Formmentioning
confidence: 99%
See 1 more Smart Citation
“…observed that finite contact duration modeling could avoid these states by low-pass filtering the mechanical responses of the VI NES [13]. Al-Shudeifat et al experimentally demonstrated that a single-sided VI NES has better damping capability than a VI NES for larger vibration shocks [14].…”
Section: Introductionmentioning
confidence: 99%