2012
DOI: 10.1016/j.ces.2012.01.050
|View full text |Cite
|
Sign up to set email alerts
|

Filtration of gases at high pressures: Permeation behavior of fiber-based media used for natural gas cleaning

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(8 citation statements)
references
References 20 publications
0
7
0
1
Order By: Relevance
“…The SiOC foams produced in this work are compared to other porous structures in the permeability map adapted from Innocentini et al, ,− , as shown in Figure S12. The map is made using experimental k 1 and k 2 data extracted from the literature and used to define the permeability of porous materials.…”
Section: Results and Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The SiOC foams produced in this work are compared to other porous structures in the permeability map adapted from Innocentini et al, ,− , as shown in Figure S12. The map is made using experimental k 1 and k 2 data extracted from the literature and used to define the permeability of porous materials.…”
Section: Results and Discussionmentioning
confidence: 99%
“…The produced ceramic foams were characterized first concerning their room temperature permeability parameters by following the same procedures described in previous works. The permeability of all batches was evaluated in a laboratory-made apparatus, with tests performed in a steady-state regime with dry airflow at room conditions ( T o = 25–29 °C, P o = P atm ≈ 94.9 kPa) on two specimens from the same batch. The pressure drop across the specimen ( P i – P o ) was measured with a digital micromanometer (0–1000 Pa, Dwyer Mark III, series 475, Michigan, USA) in response to variations in the air volumetric flow rate Q , controlled by a needle valve, and measured with rotameters (0–400 and 300–3000 L/h, Conaut, São Paulo, Brazil).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Regular cleaning of pipes will flush out substances such as scaling, hydrate and liquid accumulation. Polyester fiber membrane is widely used to remove impurities in natural gas [2] . After the treatment, the surface material composition of the membrane would be complex since the concentration of COD (Chemical Oxygen Demand), petroleum, and Fe is almost up to 1575.84 mg/L, 129.32 mg/L, 122.29 mg/L, respectively.…”
Section: Introductionmentioning
confidence: 99%
“…Filomeno (2018) utilizou a temperatura de 60°C e estudou diferentes faixas de UR (60, 70, 80 e 90 %), e constatou em sua pesquisa que a CA com 60% UR proporcionou os melhores desempenhos físicomecânicos e maior grau de carbonatação dos compósitos de fibrocimento reforçados com polpa de eucalipto. Diagrama esquemático de possíveis morfologias básicas de poros Fonte: Própria autoria A avaliação da permeabilidade em concretos, argamassas e compósitos de fibrocimento é amplamente abordada na literatura por meio de diferentes técnicas(INNOCENTINI et al, 2012;PAN et al, 2017aPAN et al, , 2017bPHUNG et al, 2015;RANJITH;VIETE, 2011;TEIXEIRA et al, 2014). No entanto, em telhas de fibrocimento é raramente encontrada alguma abordagem a respeito de permeabilidade.…”
unclassified