2006
DOI: 10.1016/j.nucengdes.2006.03.002
|View full text |Cite
|
Sign up to set email alerts
|

Film flow measurements for high-pressure diabatic annular flow in tubes with various axial power distributions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 26 publications
(2 citation statements)
references
References 6 publications
0
2
0
Order By: Relevance
“…Even if the correlation used and its implementation in the model via an UDF are not changed, going through the C language script of the UDF it has been noticed that the value of the steam velocity used in eq. 9and (10) in the previous model is the one in the interface between steam and liquid film. However, Okawa's correlation uses a bulk velocity value.…”
Section: Iii32 Entrainment Modelingmentioning
confidence: 99%
See 1 more Smart Citation
“…Even if the correlation used and its implementation in the model via an UDF are not changed, going through the C language script of the UDF it has been noticed that the value of the steam velocity used in eq. 9and (10) in the previous model is the one in the interface between steam and liquid film. However, Okawa's correlation uses a bulk velocity value.…”
Section: Iii32 Entrainment Modelingmentioning
confidence: 99%
“…In order to assess the accuracy of the model, experimental data taken by Adamsson and Anglart in 2006 are used [10]. A sketch of the experimental test section from the high-pressure two-phase flow loop at the Royal Institute of Technology (KTH) in Stockholm is shown in Figure 5.…”
Section: Iv1 Experimental Data From Adamsson and Anglartmentioning
confidence: 99%