2016
DOI: 10.1007/s10967-016-4774-9
|View full text |Cite
|
Sign up to set email alerts
|

Fifteen years of success: user access programs at the Budapest prompt-gamma activation analysis laboratory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 53 publications
0
4
0
Order By: Relevance
“…The advantages of the LEGe setups using real samples [136], representing the main scopes of our analytical practice [137], i.e. chemistry (noble-metal containing catalysts [138], [139]), cultural heritage science (ancient silver coins [140]), and material science (ternary Co-Cr-Re alloys [141]) will be detailed later in chapter 4.2.1.…”
Section: Improving the Selectivity Of Pgaa With A High-resolution Ger...mentioning
confidence: 99%
See 1 more Smart Citation
“…The advantages of the LEGe setups using real samples [136], representing the main scopes of our analytical practice [137], i.e. chemistry (noble-metal containing catalysts [138], [139]), cultural heritage science (ancient silver coins [140]), and material science (ternary Co-Cr-Re alloys [141]) will be detailed later in chapter 4.2.1.…”
Section: Improving the Selectivity Of Pgaa With A High-resolution Ger...mentioning
confidence: 99%
“…In our daily laboratory routine, there is a growing interest for the analysis of the ancient copper-based alloys, too [137]. To offer the best service, the different methods available at our laboratory were compared from the point of view of their performances.…”
Section: Comparison Of the Performances Of Pgaa Inaa In-beam Activati...mentioning
confidence: 99%
“…In the last 15 years, Hypermet PC [17][18][19] has been the ultimate evaluation software at the Budapest PGAA facility to analyze the prompt gamma spectra, allowing the generation of accurate nuclear data [20][21] and reliable element analysis results [22]. However, over the years, the above listed limitations of the software are realized and attempts were made to overcome them by developing an adequate piece of software.…”
Section: Introductionmentioning
confidence: 99%
“…The 2017 Lindstrom paper[Lindstrom and Révay 2017] provides a more recent review of PGAA and describes new instruments installed in the last 10 years in Argentina, Brazil, China, India, Japan, as well as US university facilities at Oregon State and the University of Texas. More established PGAA facilities in Budapest[Belgya 2012] [Szentmiklósi et al 2016], and at the National Institute of Standard and Technology in Maryland[Paul et al 2015] have led to breakthroughs in the last 5 years in archaeological research[Maróti et al 2020] [Livingston et al 2018] [Jwa et al 2018] [Kluge et al 2018], materials science[Otsuki et al 2019] [Miura and Matsue 2016] [Artnak et al 2018, food science[Fukushima et al 2014], and energy research[Stieghorst et al 2018].…”
mentioning
confidence: 99%