2021
DOI: 10.1002/bio.4125
|View full text |Cite
|
Sign up to set email alerts
|

Field studies of bioluminescence in the Antarctic sector of the Atlantic Ocean in 2002 and 2020

Abstract: In this work, IBSS materials on seawater bioluminescence intensity changes in the Atlantic sector of the Antarctic Ocean (the Weddell Sea area) with an interval of almost 20 years are presented. Data were obtained using a single instrument, the hydrobiophysical system Salpa‐M, in the area of 50–63°S, 62–49°W in March 2002 (183 soundings at 45 stations during cruise 7 on RV Gorizont) and in February 2020 (122 soundings at 18 stations during cruise 79 on RV Academic Mstislav Keldysh). The bioluminescence studies… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 13 publications
(14 reference statements)
0
8
0
Order By: Relevance
“…In the previous studies, it was stated that during the second half of the twentieth century, BF was mainly formed by phytoplankton and krill, whereas the latest 20 years have seen extensive fields of luminous salps along with a significant decrease in the amount of phytoplankton. [ 22 ]…”
Section: Resultsmentioning
confidence: 99%
“…In the previous studies, it was stated that during the second half of the twentieth century, BF was mainly formed by phytoplankton and krill, whereas the latest 20 years have seen extensive fields of luminous salps along with a significant decrease in the amount of phytoplankton. [ 22 ]…”
Section: Resultsmentioning
confidence: 99%
“…The bathyphotometer SALPA-M includes a bioluminescence sensor with sensitivity from 10 À12 to 10 -8 W cm -2 L À1 . [23] The temperature sensor…”
Section: Methodsmentioning
confidence: 99%
“…The bathyphotometer SALPA‐M includes a bioluminescence sensor with sensitivity from 10 −12 to 10 –8 W cm –2 L −1 . [ 23 ] The temperature sensor covered measurements in the range −3 o C to +35 o C. To calibrate the bioluminescence sensor, a radioactive–luminescence light source was used. The depth of the submersible gear was estimated by means of the pressure sensor with a precision of 0.01 MPa.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The bathyphotometer 'SALPA' used for BP measurements has a dynamic band of 57 db and the sensitivity of the bioluminescence sensor from 10 À13 to 10 À8 W cm À2 L À1 with a band of spectral sensitivity from 160 to 600 nm. [11,12] To calibrate the bioluminescence sensor, a radioactive-luminescent light source was used. The depth of the submersible gear was estimated by means of the pressure sensor with a precision of 0.01 MPa.…”
Section: Bioluminescent Potentialmentioning
confidence: 99%