2015
DOI: 10.3938/jkps.66.317
|View full text |Cite
|
Sign up to set email alerts
|

Field measurement facility for the PAL-XFEL undulator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 2 publications
0
1
0
Order By: Relevance
“…L C is a fixed variable and PI u is an independent variable for the different K, while PI ps can be a practical control parameter easily controlled by changing the gap of the phase-shifter. The magnetic field measurement for the undulator and the phase-shifter was carried out at the field measurement lab, where the ambient temperature and earth magnetic field were controlled the same as that at the installation site in the undulator hall of PAL-XFEL [10,21]. Particularly, the ambient temperature variations should be better than ±0.1 • C to minimize the field variation of the magnetic block [21,22].…”
Section: Phase-shifter To Compensate For the Slippagementioning
confidence: 99%
See 1 more Smart Citation
“…L C is a fixed variable and PI u is an independent variable for the different K, while PI ps can be a practical control parameter easily controlled by changing the gap of the phase-shifter. The magnetic field measurement for the undulator and the phase-shifter was carried out at the field measurement lab, where the ambient temperature and earth magnetic field were controlled the same as that at the installation site in the undulator hall of PAL-XFEL [10,21]. Particularly, the ambient temperature variations should be better than ±0.1 • C to minimize the field variation of the magnetic block [21,22].…”
Section: Phase-shifter To Compensate For the Slippagementioning
confidence: 99%
“…The magnetic field measurement for the undulator and the phase-shifter was carried out at the field measurement lab, where the ambient temperature and earth magnetic field were controlled the same as that at the installation site in the undulator hall of PAL-XFEL [10,21]. Particularly, the ambient temperature variations should be better than ±0.1 • C to minimize the field variation of the magnetic block [21,22]. The phase slippage along the free space with a distance of L D between undulator segments is [23]…”
Section: Phase-shifter To Compensate For the Slippagementioning
confidence: 99%
“…This undulator is to be installed into the beamline in February 2021. A measurement system consisting of 3-D Hall probe with three Bell 1-D Hall sensors and a single stretched wire [7] were used for the measurements. The measurements were carried out before and after pole tuning, by changing the vertical offset to the magnetic field center.…”
Section: Pal-xfel Undulator Off-axis Field Errormentioning
confidence: 99%