2006
DOI: 10.1109/tpwrd.2005.861231
|View full text |Cite
|
Sign up to set email alerts
|

Field Experiences With Measurements of Dielectric Response in Frequency Domain for Power Transformer Diagnostics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
39
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 97 publications
(42 citation statements)
references
References 2 publications
0
39
0
Order By: Relevance
“…At the same time, ε 1 is increasing with the increase of the polarization intensity [28]. The complex correlations between polarization intensity and the speed of polarization result in the "deceleration zone" in a certain frequency band, which is determined by the measuring temperature, oil paper constituents, aging time, and moisture content [24,29]. Because the insulation structure of the capacitance core in the oil-paper bushing is relatively simple, the polarization of the oil-paper is weaker than that of the transformer oil-paper.…”
Section: How Aging and Moisture Content Affect Tan δmentioning
confidence: 99%
See 1 more Smart Citation
“…At the same time, ε 1 is increasing with the increase of the polarization intensity [28]. The complex correlations between polarization intensity and the speed of polarization result in the "deceleration zone" in a certain frequency band, which is determined by the measuring temperature, oil paper constituents, aging time, and moisture content [24,29]. Because the insulation structure of the capacitance core in the oil-paper bushing is relatively simple, the polarization of the oil-paper is weaker than that of the transformer oil-paper.…”
Section: How Aging and Moisture Content Affect Tan δmentioning
confidence: 99%
“…The results show that the higher the initial moisture content, the faster decline in DP of insulating paper in the aging process. This phenomenon can be explained by the hydrolysis of cellulose [24]. In addition, hydrogen bonds between the moisture and the insulation paper can reduce the number of hydrogen bonds between the cellulose chains, thus reducing the stability of the molecular chains and increasing the breaking of cellulose.…”
Section: Polymerization Degree (Dp) Of the Insulating Paper And Insulmentioning
confidence: 99%
“…Furthermore, in previous studies it has been identified that measuring capacitance between HV and LV (CHL) is least affected by external factors [14]. However in certain circumstances, such as in an auto transformer, winding configuration does not support CHL measurements.…”
Section: Measurement Configurationmentioning
confidence: 99%
“…The usual measurement time for a cycle of FDS measurement could be up to four times the length of the period of the lowest frequency [13]. Numerous studies performed on field application of FDS measurements have revealed that measurement between HV to LV is least affected by different external factors such as bushing conditions, connection configurations and weather conditions [14]. Modeling the FDS response has also been widely discussed.…”
Section: Introductionmentioning
confidence: 99%
“…Blennow [19] studied measurement of moisture content in field transformer based on field experience, and presented that precautions should be taken with the results to minimize effects caused by equipment remaining connected to the transformer as well as by external conditions, while the internal relationship between aging and moisture had not be explored. Belén García and Juan Carlos Burgos' studies [20][21][22] focused on moisture diffusion in oil-paper insulation, and explored the influence of temperature, thickness of cardboard, aging and other factors on moisture diffusion coefficient between oil and paper.…”
Section: Introductionmentioning
confidence: 99%