2018
DOI: 10.3390/ijerph15091958
|View full text |Cite
|
Sign up to set email alerts
|

Field Evaluation of N95 Filtering Facepiece Respirators on Construction Jobsites for Protection against Airborne Ultrafine Particles

Abstract: Exposure to high concentrations of airborne ultrafine particles in construction jobsites may play an important role in the adverse health effects among construction workers, therefore adequate respiratory protection is required. The performance of particulate respirators has never been evaluated in field conditions against ultrafine particles on construction jobsites. In this study, respiratory protection levels against ultrafine particles of different size ranges were assessed during three common construction… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(13 citation statements)
references
References 36 publications
0
13
0
Order By: Relevance
“…Whereas some studies use a manikin headform with the full mask (Balazy et al, 2006a,b;He et al, 2013;Bahloul et al, 2014;Shakya et al, 2016;Adhikari et al, 2018;Kumar et al, 2020), other studies cut a portion of the mask/fabric and place it in a filter holder (Eshbaugh et al, 2008;Lin et al, 2017;Konda et al, 2020;Pei et al, 2020;Wang et al, 2020). Many studies use salt, e.g., NaCl (Eshbaugh et al, 2008;He et al, 2014;Lin et al, 2017;Pei et al, 2020), or polystyrene latex (PSL) spherical particles of defined sizes (Qian et al, 1997;Lee et al, 2005;Eshbaugh et al, 2008) to simulate particulate contaminants.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
See 2 more Smart Citations
“…Whereas some studies use a manikin headform with the full mask (Balazy et al, 2006a,b;He et al, 2013;Bahloul et al, 2014;Shakya et al, 2016;Adhikari et al, 2018;Kumar et al, 2020), other studies cut a portion of the mask/fabric and place it in a filter holder (Eshbaugh et al, 2008;Lin et al, 2017;Konda et al, 2020;Pei et al, 2020;Wang et al, 2020). Many studies use salt, e.g., NaCl (Eshbaugh et al, 2008;He et al, 2014;Lin et al, 2017;Pei et al, 2020), or polystyrene latex (PSL) spherical particles of defined sizes (Qian et al, 1997;Lee et al, 2005;Eshbaugh et al, 2008) to simulate particulate contaminants.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…Many studies use salt, e.g., NaCl (Eshbaugh et al, 2008;He et al, 2014;Lin et al, 2017;Pei et al, 2020), or polystyrene latex (PSL) spherical particles of defined sizes (Qian et al, 1997;Lee et al, 2005;Eshbaugh et al, 2008) to simulate particulate contaminants. The particle concentration used in these experiments varies from hundreds to several tens of thousands of particles per cm 3 (Balazy et al, 2006a,b;Eshbaugh et al, 2008;He et al, 2014;Adhikari et al, 2018). A variety of flow rates were used in these tests (Eshbaugh et al, 2008;He et al, 2013;Bahloul et al, 2014;Adhikari et al, 2018), yet the most…”
Section: Accepted Manuscriptmentioning
confidence: 99%
See 1 more Smart Citation
“…Interestingly, such a particle size corresponds to the 300 nm particulate size threshold used for grading the filtration efficiency of masks (5) and the most penetrating particle size of single-filter masks (6). Moreover, in field tests, investigators have reported poor performance of N95 masks (7). A key reason for such a finding may have been poor mask seal afforded by N95 masks which could be prevented by elastomeric linings.…”
Section: Introductionmentioning
confidence: 99%
“…In todays' workplace, filtering facepiece respirators (FFR) are frequently used by indoor/outdoor workers to reduce exposure to airborne particulate pollution (Chen et al, 2016;Adhikari et al, 2018). An air-purifying respirator such as the N95 FFR or the P100 FFR collects 95-99.9% of the most penetrating size aerosol, so wearing them in indoor/outdoor working areas can minimize exposure to air pollution.…”
Section: Respirators Vs Nasal Filtersmentioning
confidence: 99%