2014
DOI: 10.1016/j.jmr.2014.01.003
|View full text |Cite
|
Sign up to set email alerts
|

FID-SPI pulse sequence for quantitative MRI of fluids in porous media

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 16 publications
0
8
0
Order By: Relevance
“…Therefore, this uncertainty will be propagated to the output of the gradient amplifier and will directly impact the magnetic field gradient waveform as experienced by the sample. The uncertainty of the pre‐equalized gradient waveform applied for an experiment (such as FID‐SPI ) will remain identical to that of the initial MFGM measurement employed to characterize the system. For example, the uncertainty of a pre‐equalized gradient waveform based on a MFGM measurement with 64 scans is identical to that of the MFGM measurement (which is 0.42% as shown in Table ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, this uncertainty will be propagated to the output of the gradient amplifier and will directly impact the magnetic field gradient waveform as experienced by the sample. The uncertainty of the pre‐equalized gradient waveform applied for an experiment (such as FID‐SPI ) will remain identical to that of the initial MFGM measurement employed to characterize the system. For example, the uncertainty of a pre‐equalized gradient waveform based on a MFGM measurement with 64 scans is identical to that of the MFGM measurement (which is 0.42% as shown in Table ).…”
Section: Resultsmentioning
confidence: 99%
“…Nevertheless, large‐scale gradient distortions may be measured and corrected when MFGM and pre‐equalization techniques are employed . Alternative field correction approaches such as MFM or k‐space trajectory approaches are required when higher resolution magnetic field corrections are necessary.…”
Section: Resultsmentioning
confidence: 99%
“…Besides medical applications such as the imaging of bones, tendons, or certain parts of the brain [ 19 , 20 ], these methods are of high convenience in the geo- and material sciences. Examples are fluid content imaging using SPRITE in rock cores [ 21 , 22 , 23 ] or mortar [ 24 ]. SPRITE is also especially convenient for rapid moisture profiling combined with relaxation time analysis in soil cores [ 25 ].…”
Section: Introductionmentioning
confidence: 99%
“…To improve sensitivity, a number of other SPI methods have been proposed. In free induction decay (FID) SPI, the gradients are switched off during the receiver event, which enables significant improvements in SNR . Hybrid spin‐echo (SE) SPI offers similar SNR advantages .…”
Section: Introductionmentioning
confidence: 99%
“…In free induction decay (FID) SPI, the gradients are switched off during the receiver event, which enables significant improvements in SNR. 15 Hybrid spin-echo (SE) SPI offers similar SNR advantages. 16 So far, these techniques are mainly used for T * 2 or T 2 -weighted and diffusion-weighted imaging.…”
Section: Introductionmentioning
confidence: 99%