2004
DOI: 10.1177/089686080402400312
|View full text |Cite
|
Sign up to set email alerts
|

Fibrin Glue Used Successfully in Peritoneal Dialysis Catheter Leakage in Children

Abstract: Background Acute renal failure in infants and small children is generally treated with peritoneal dialysis (PD). Dialysis has to be started immediately after catheter implantation. Early dialysate leakage can complicate the effectiveness of dialysis. Fibrin glue applied to the external part of the tunnel may stop dialysate leakage and eliminate the need for surgical intervention. The use of fibrin glue in the treatment of PD catheter leakage in children was studied. Methods Fibrin glue was used in 8 children (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
1

Year Published

2011
2011
2022
2022

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(8 citation statements)
references
References 16 publications
(4 reference statements)
0
7
0
1
Order By: Relevance
“…In a small study of 8 children in which there was dialysate leakage in the first 24 – 48 hours of dialysis, fibrin glue was applied (1 mL) to the external part of the catheter at the exit site. No recurrence of dialysate leakage was seen in any of the 8 children (86).…”
Section: Guideline P2: Access and Fluid Delivery For Acute Pd In Childrenmentioning
confidence: 89%
See 2 more Smart Citations
“…In a small study of 8 children in which there was dialysate leakage in the first 24 – 48 hours of dialysis, fibrin glue was applied (1 mL) to the external part of the catheter at the exit site. No recurrence of dialysate leakage was seen in any of the 8 children (86).…”
Section: Guideline P2: Access and Fluid Delivery For Acute Pd In Childrenmentioning
confidence: 89%
“…Overall, there was no difference in mortality between PD and extracorporeal RRT in both the observational studies (odds ratio (OR), 0.96; 95% confidence interval (CI), 0.53–1.71) and the 4 RCTs (OR, 1.50; 95% CI, 0.46–4.86). Three of the RCTs were conducted primarily among septic or critically ill patients (77-100% of cases). Gabriel et al ‘s randomized trial was well conducted; however, it has been criticized for flaws in randomization, inclusion criteria, and not being powered to detect a mortality difference (7).…”
Section: Adult Guidelinesmentioning
confidence: 99%
See 1 more Smart Citation
“…Infuse fibrin glue between the catheter and the tunnel wall. 91,92 (Some clinicians use fibrin glue in this way to prevent catheter leak. )…”
Section: Rationalementioning
confidence: 99%
“…Если разрыв брюшины близок к паховой области, может отмечаться отек гениталий. Предупредить утечки диализата в раннем послеоперационном периоде можно с помощью фибринового клея, который наносят на месте выхода, причем клей применяют как с профилактической, так и с лечебной целью [3,27,28].…”
Section: утечкиunclassified