2008
DOI: 10.1088/1464-4258/10/4/044012
|View full text |Cite
|
Sign up to set email alerts
|

Fiber optic tunable probe for endoscopic optical coherence tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 41 publications
(25 citation statements)
references
References 20 publications
0
25
0
Order By: Relevance
“…The lengths of the rings were set so that OPD R = -20 mm. In order to superpose the two signals originating from the fundamental channel and from the first re-circulation channel, the frequency of the carrier was altered to 180 kHz to satisfy the condition (6).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The lengths of the rings were set so that OPD R = -20 mm. In order to superpose the two signals originating from the fundamental channel and from the first re-circulation channel, the frequency of the carrier was altered to 180 kHz to satisfy the condition (6).…”
Section: Resultsmentioning
confidence: 99%
“…In swept source (SS)-OCT imaging systems, the spectral resolution is determined by the instantaneous line-width of the swept source [5]. Narrow line-width SSs have been reported, which makes SS-OCT more suitable to imaging long axial samples than FD-OCT. Long axial range imaging is necessary in endoscopy, small animal imaging, or anterior segment imaging of the human eye where at least 1 cm axial range with good sensitivity is required [6][7][8].…”
Section: Introductionmentioning
confidence: 99%
“…In our opinion, this could open the route for potential impacts either for future blood diagnostics and in vivo endoscopy. Recent improvement in biophotonics as the manipulation of RBCs from the outside of the vein 16 and, at the same time, new papers on the miniaturization of OT on a single fibre 17,43,44 could convincingly lead to envisage an integration of the presented technique for endoscopy. For example, it could be investigated a fibre-based system able to manipulate and trap RBCs inside the vein.…”
Section: Discussionmentioning
confidence: 99%
“…These features are very important for handheld OCT device. It is well-known that the OCT reflectance is a unimodal function of focal plane position and the maximum OCT reflectance value is obtained when the sample is located at the focal plane [23]. Thus the search for the optimum focal plane becomes an extremum search problem of a unimodal function.…”
Section: Golden-section Search Based Automatic Focus Tuningmentioning
confidence: 99%