2020
DOI: 10.1016/j.bios.2019.111871
|View full text |Cite
|
Sign up to set email alerts
|

Fiber optic nanogold-linked immunosorbent assay for rapid detection of procalcitonin at femtomolar concentration level

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
45
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 61 publications
(50 citation statements)
references
References 31 publications
0
45
0
Order By: Relevance
“…However, for certain diseases, the concentration of target molecules/pathogens are at extremely low level. With the adoption of our recently developed fiber optic nanogold-linked immunosorbent assay (FONLISA) in FOPPR biosensor which exhibits fM sensitivity [15], we believe that the FOPPR biosensing The accuracy of the results by the FOPPR biosensor for the analysis of HLA-B27 mRNA was compared with that by the real-time RT-PCR method using six extracted blood samples from AS patients. As shown in Figure 9b, comparison of the results by the two methods performed by linear correlation analysis shows a correlation coefficient of 0.991 and a p value < 0.0001 at the 95% level of significance, indicating that the results arising from both methods align.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, for certain diseases, the concentration of target molecules/pathogens are at extremely low level. With the adoption of our recently developed fiber optic nanogold-linked immunosorbent assay (FONLISA) in FOPPR biosensor which exhibits fM sensitivity [15], we believe that the FOPPR biosensing The accuracy of the results by the FOPPR biosensor for the analysis of HLA-B27 mRNA was compared with that by the real-time RT-PCR method using six extracted blood samples from AS patients. As shown in Figure 9b, comparison of the results by the two methods performed by linear correlation analysis shows a correlation coefficient of 0.991 and a p value < 0.0001 at the 95% level of significance, indicating that the results arising from both methods align.…”
Section: Discussionmentioning
confidence: 99%
“…However, for certain diseases, the concentration of target molecules/pathogens are at extremely low level. With the adoption of our recently developed fiber optic nanogold-linked immunosorbent assay (FONLISA) in FOPPR biosensor which exhibits fM sensitivity [15], we believe that the FOPPR biosensing equatmethodology can also be applied to the detection of SARS-CoV-2, a positive-sense single-stranded RNA (ssRNA) virus, which has resulted in the recent global COVID-19 outbreak, and will continue to broaden the application fields in molecular biology and biomedical diagnosis.…”
Section: Discussionmentioning
confidence: 99%
“…For larger and structurally complex molecules such as antibiotics, split-aptamers have not been probed as receptors but hold promise as even conventional aptasensors have allowed group-specific nanomolar detections [162]. Optical fibre-based sandwich immunosensors frequently employ AuNPs for signal enhancement which allows ultrasensitive and rapid detection [163,164]. Liu's group developed an EW immunosensor using antibody labelled fluorophores for xenoestrogens which are molecules that mimic the structure of estrogen compounds and interfere with the functions of endogenous estrogens [165].…”
Section: Evanescent Wave-based Sensors For Biomedical Diagnosticsmentioning
confidence: 99%
“…Several methods have been reported for PCT determination, mainly based in the selective recognition provided by immunological interactions. These methodologies include immunoturbidimetric assays [9], chemiluminescent immunoassays [10][11][12][13][14][15][16], immunochromatographic assays [17][18][19][20][21][22], surface plasmon resonance biosensors [23][24][25], fluorescence immunosensors [26][27][28][29][30][31][32], ellipsometry immunosensors [33], colorimetric immunoassays [34][35][36], and electrochemical immunoassays [37][38][39][40][41][42][43][44][45][46][47][48][49][50][51][52][53][54][55][56]. Even differen...…”
Section: Introductionmentioning
confidence: 99%
“…In this sense, they constitute an ideal platform to perform integrated microscale immunoassays [59][60][61][62][63][64]. Despite these inherent advantages, few microfluidic immunosensors for PCT determination have been previously published, and most of them are based on optical techniques [26,[28][29][30]39].…”
Section: Introductionmentioning
confidence: 99%