2006
DOI: 10.1039/b510717b
|View full text |Cite
|
Sign up to set email alerts
|

Fiber-optic infrared reflectance spectroelectrochemical studies of osmium and ruthenium nitrosyl porphyrins containing alkoxide and thiolate ligands

Abstract: We have examined the redox behavior of the osmium and ruthenium compounds (OEP)M(NO)(OEt) and (OEP)M(NO)(SEt) (OEP = octaethylporphyrinato dianion; M = Os, Ru) by cyclic voltammetry and infrared spectroelectrochemistry. The compound (OEP)Os(NO)(OEt) undergoes a single reversible oxidation process in dichloromethane. In contrast, the thiolate compound (OEP)Os(NO)(SEt) undergoes a net irreversible oxidation resulting in formal loss of the SEt ligand. Extended Hückel calculations on crystal structures of these tw… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
21
0

Year Published

2011
2011
2017
2017

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 21 publications
(22 citation statements)
references
References 34 publications
1
21
0
Order By: Relevance
“…A Bruker Vector 22 and/or a Tensor 27 FTIR spectrometer equipped with a mid-IR fiber-optic dip probe and liquid nitrogen cooled MCT detector (RemSpec Corporation, Sturbridge, MA, USA) were used for the infrared spectroelectrochemistry. [12,41,42] The electrochemical experiments were performed in triplicate to determine reproducibilities. X-ray diffraction data were collected using a diffractometer with a Bruker APEX ccd area detector and graphite-monochromated Mo-K α radiation (λ = 0.71073 Å).…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…A Bruker Vector 22 and/or a Tensor 27 FTIR spectrometer equipped with a mid-IR fiber-optic dip probe and liquid nitrogen cooled MCT detector (RemSpec Corporation, Sturbridge, MA, USA) were used for the infrared spectroelectrochemistry. [12,41,42] The electrochemical experiments were performed in triplicate to determine reproducibilities. X-ray diffraction data were collected using a diffractometer with a Bruker APEX ccd area detector and graphite-monochromated Mo-K α radiation (λ = 0.71073 Å).…”
Section: Methodsmentioning
confidence: 99%
“…In all the electrochemical experiments, a three-electrode cell was utilized and consisted of a 3.0-mm diameter Pt disk working electrode, a Pt wire counter electrode, and a Ag/AgCl reference electrode. [12,41,42] Solutions were deaerated before use by passing a stream of N 2 gas through the solution for a minimum of 10 min. A blanket of N 2 was maintained over the solution while performing the experiment; care was taken to minimize evaporative cooling due to N 2 flow in the headspace, as this could cause rolling baselines in the resulting IR difference spectra.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations