2000
DOI: 10.1109/22.899020
|View full text |Cite
|
Sign up to set email alerts
|

Fiber-edge electrooptic/magnetooptic probe for spectral-domain analysis of electromagnetic field

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
35
0

Year Published

2003
2003
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 80 publications
(36 citation statements)
references
References 7 publications
1
35
0
Order By: Relevance
“…Otherwise, to the best of our knowledge, there has been no report on the scanning free method for the H-MWNF imaging. The reported sensitivity of the scanning method based on the magneto optical effect with an optical scanning probe is around 0.03 mW10. However, this sensitivity is achieved by a noise reduction of the measurement system, and the MO effect by the H-WMNF is extremely weak so that it cannot be detected by a typical CCD camera16.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Otherwise, to the best of our knowledge, there has been no report on the scanning free method for the H-MWNF imaging. The reported sensitivity of the scanning method based on the magneto optical effect with an optical scanning probe is around 0.03 mW10. However, this sensitivity is achieved by a noise reduction of the measurement system, and the MO effect by the H-WMNF is extremely weak so that it cannot be detected by a typical CCD camera16.…”
Section: Resultsmentioning
confidence: 99%
“…Various approaches have been proposed based on different kinds of physical phenomena45678910111213. They often rely on scanning probe techniques with carefully designed scanning probes, particular materials and physical processes.…”
mentioning
confidence: 99%
“…Thus, the LEI optics system works as a mixer in the optical regime. The intensity of the IF component , which corresponds to the electric field intensity, is given by (4) and is proportional to the input light intensity and the square of the modulation depth by the electrooptic sensor .…”
Section: A Photonic Heterodyne Methodsmentioning
confidence: 99%
“…Meanwhile, high sensitivity [2], [3] and extremely low invasiveness [4], [5] are achieved in conventional single-channel systems. It is expected that LEI systems will be used for high-speed imaging under various conditions, and details of the electromagnetic field will be measured with single-channel systems.…”
Section: Lei Performancementioning
confidence: 99%
“…Moreover, the size of UWB antennae make them incompatible with measurements inside equipments of reduced size. The recent development of pigtailed electrooptic (EO) sensors [2] could constitute a competitive alternative to antennae as they can bring solutions to the above-mentioned drawbacks. However, EO probes that were developed up to now suffer from the drift of their response with the temperature.…”
Section: Introductionmentioning