2022
DOI: 10.1080/02564602.2022.2069608
|View full text |Cite
|
Sign up to set email alerts
|

Fiber Bragg Gratings in Healthcare Applications: A Review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 105 publications
0
4
0
Order By: Relevance
“…FBG sensors utilize the phenomenon of Bragg reflection to measure various physical variables such as strain, temperature, pressure, and acceleration [ 143 , 144 ]. They are widely used in industries such as aerospace, civil engineering, oil and gas, and structural health monitoring [ 145 ].…”
Section: Most Widely Employed Optical Fibre Configurations In Sensing...mentioning
confidence: 99%
“…FBG sensors utilize the phenomenon of Bragg reflection to measure various physical variables such as strain, temperature, pressure, and acceleration [ 143 , 144 ]. They are widely used in industries such as aerospace, civil engineering, oil and gas, and structural health monitoring [ 145 ].…”
Section: Most Widely Employed Optical Fibre Configurations In Sensing...mentioning
confidence: 99%
“…In biomedical analysis, especially, FBGs have shown a prominent resolve regarding their reliability, ruggedness, and operation versatility. Various works were reported regarding cardiorespiratory analysis, gait analysis, prosthetics, and wearable sensors belonging to the striking subfield fields of biomedical research [19][20][21][22]. Considering works related to the application of optical sensors and FBG in plantar pressure and gait monitoring, several works have been reported in the past.…”
Section: Introductionmentioning
confidence: 99%
“…where n eff is the effective refractive index, L is the period of the index, α and η are the thermal coefficients, DT is the temperature change, r e is the photoelastic coefficient, and e z is the strain applied [20]. As explained before, in the present work, arrays (each array has two FBGs) are utilized for acquiring the data.…”
Section: Introductionmentioning
confidence: 99%
“…S INCE their discovery, the exploitation of fiber Bragg grating (FBG) sensors burst in a variety of fields and are nowadays widely leveraged in medical and biomedical applications [1], [2], [3], [4]. Their popularity is driven by a number of distinctive features such as their biological compatibility, nontoxicity, reduced size, inherent safety, electromagnetic disturbance immunity, and capacity for multiplexing [5].…”
Section: Introductionmentioning
confidence: 99%