2022
DOI: 10.1117/1.nph.9.3.032212
|View full text |Cite
|
Sign up to set email alerts
|

Fiber-based lactate recordings with fluorescence resonance energy transfer sensors by applying an magnetic resonance-informed correction of hemodynamic artifacts

Abstract: . Significance: Fluorescence resonance energy transfer (FRET) sensors offer enormous benefits when studying neurophysiology through confocal microscopy. Yet, their use for fiber-based in vivo recordings is hampered by massive confounding effects and has therefore been scarcely reported. Aim: We aim to investigate whether in vivo fiber-based lactate recordings in the rodent brain are feasible with FRET sensors and impl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
4
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 71 publications
1
4
0
Order By: Relevance
“…S5 , details in Methods), the DMN is presented in Fig.4d , including prelimbic cortex, cingulate cortex, auditory cortex, posterior parietal cortex, and retrosplenial cortex. These results provide strong evidence for highly reliable detection of BOLD fMRI signals under experimental conditions, which are highly consistent with reports from other researchers [37-42].…”
Section: Resultssupporting
confidence: 92%
“…S5 , details in Methods), the DMN is presented in Fig.4d , including prelimbic cortex, cingulate cortex, auditory cortex, posterior parietal cortex, and retrosplenial cortex. These results provide strong evidence for highly reliable detection of BOLD fMRI signals under experimental conditions, which are highly consistent with reports from other researchers [37-42].…”
Section: Resultssupporting
confidence: 92%
“…2021 ; Jung et al. 2022 ; Lambers et al. 2022 ), providing strong evidence for highly reliable detection of BOLD fMRI signals under experimental conditions without any modification or complication of the experimental procedure.…”
Section: Resultsmentioning
confidence: 97%
“…(7) LFP recordings were conducted. A total of 10% of the data were included retrospectively from previous studies (Albers et al, 2019;van Alst et al, 2019;Lambers et al, 2022). Therefore, temporal resolution of MR measurements varied.…”
Section: Animal Handling and Data Overviewmentioning
confidence: 99%
“…This is not only relevant for fMRI, but for all techniques that are sensitive to hemodynamic changes. In addition to optical recordings of blood volume or flow and laser doppler flowmetry, this also applies to optical recordings of fluorescent dyes, as hemodynamic changes cause artifacts in these measurements (Kozberg et al, 2016;Ma et al, 2016;Lambers et al, 2022;Zhang et al, 2022).…”
Section: Hemodynamic Oscillations Occur In Both Small and Large Blood...mentioning
confidence: 99%