2015
DOI: 10.3109/14767058.2015.1015413
|View full text |Cite
|
Sign up to set email alerts
|

Fetal ductus arteriosus constriction and closure: analysis of the causes and perinatal outcome related to 45 consecutive cases

Abstract: The results of this study indicate that clinically significant ductal constriction may follow maternal exposure to single doses of NSAIDs. Unknown causes or other new substances were also described, such as naphazoline, fluoxetine, isoxsuprine, caffeine and pesticides. Echocardiographic diagnosis of ductal constriction led to an active medical approach that resulted in low morbidity of this group of patients.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
51
0
10

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 54 publications
(61 citation statements)
references
References 23 publications
0
51
0
10
Order By: Relevance
“…In this case series analysis, we retrieved and discussed 25 cases of fetal ductus arteriosus constriction or closure, and thereby provided evidence on the likely causal relationship with maternal paracetamol intake. Although robust data on its incidence are absent, fetal ductus arteriosus constriction or closure is rare, with two recent retrospective case series on, respectively, 45 and 22 consecutive cases in datasets of 26 000 (0.17%) and 1602 (1.4%) referrals for fetal echocardiography [20,27]. The specific setting of fetal physiology necessitates patency of the fetal ductus arteriosus to bypass fetal blood flow from the pulmonary artery to the systemic circulation under low pressure and low resistance settings.…”
Section: Discussionmentioning
confidence: 99%
“…In this case series analysis, we retrieved and discussed 25 cases of fetal ductus arteriosus constriction or closure, and thereby provided evidence on the likely causal relationship with maternal paracetamol intake. Although robust data on its incidence are absent, fetal ductus arteriosus constriction or closure is rare, with two recent retrospective case series on, respectively, 45 and 22 consecutive cases in datasets of 26 000 (0.17%) and 1602 (1.4%) referrals for fetal echocardiography [20,27]. The specific setting of fetal physiology necessitates patency of the fetal ductus arteriosus to bypass fetal blood flow from the pulmonary artery to the systemic circulation under low pressure and low resistance settings.…”
Section: Discussionmentioning
confidence: 99%
“…60 The right ventricular Tei index is increased in ductal constriction secondary to shortened ejection time, and returns to baseline coincident with ductal relaxation. 59 Tricuspid regurgitation is often seen and can be used to establish that high right ventricular systolic pressure is present.…”
Section: Ductal Constrictionmentioning
confidence: 98%
“…Postnatal management should focus on therapies to reduce PVR which will improve right heart hemodynamics and lead to less right-to-left PFO shunting and cyanosis. Fetuses that can escape this neonatal period without extreme prematurity, hydrops, or RV failure have good long-term prognosis [9,10].…”
Section: Discussionmentioning
confidence: 99%