1999
DOI: 10.1002/(sici)1521-3765(19990604)5:6<1874::aid-chem1874>3.0.co;2-2
|View full text |Cite
|
Sign up to set email alerts
|

Ferrimagnetic Behavior ofmeso-Tetrakis(2,3,5,6-tetrafluoro-4-methoxyphenyl)porphyrinatomanganese(iii) tetracyanoethenide, [MnTF4OMePP][tcne]⋅2 PhMe: Structural Evidence for a Second-Order Crystallographic Phase Transition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

10
32
0

Year Published

1999
1999
2012
2012

Publication Types

Select...
10

Relationship

6
4

Authors

Journals

citations
Cited by 21 publications
(42 citation statements)
references
References 0 publications
10
32
0
Order By: Relevance
“…These changes are reversible. Although the details of this behaviour are unclear, it is attributable to the onset of a non-uniform 1-D chain and/or a phase transition, 15 and might be attributable to the short Fe-N TCNE coordination bonding.…”
Section: Spectroscopic Studiesmentioning
confidence: 99%
“…These changes are reversible. Although the details of this behaviour are unclear, it is attributable to the onset of a non-uniform 1-D chain and/or a phase transition, 15 and might be attributable to the short Fe-N TCNE coordination bonding.…”
Section: Spectroscopic Studiesmentioning
confidence: 99%
“…Since then additional porphyrin-based magnets have been prepared and characterized; however, a complete understanding of the magnetic behavior of this class of materials is still under investigation . Due to the relative ease of modifying the porphyrin structure, we and others , have prepared a series of substituted tetraphenylporphyrin TCNE electron transfer salts with the hope of establishing a structure−function relationship.…”
Section: Introductionmentioning
confidence: 99%
“…These deviations are difficult to identify, as they could originate in various computational and/or experimental sources (possible experimental sources could be: (a) a poor quality of the experimental magnetic data or the models used to obtain the experimental J AB parameters, (b) the use of high temperature structures, because the thermal ). 39 Interestingly, a linear fitting of the computed versus the experimental data has a similar slope (0.18 in the CASSCF, 0.25 in the CASPT2, and 0.35 in the B3LYP sets). The computed and experimental values of J AB , as a function of the a angle and the d29 dihedral angle, are shown in Fig.…”
Section: Calibration Of the Theoretical Calculation Of J Ab On [Mn(po...mentioning
confidence: 72%