2018
DOI: 10.1155/2018/5909346
|View full text |Cite
|
Sign up to set email alerts
|

Feedforward Harmonic Mitigation Strategy for Single-Phase Voltage Source Converter

Abstract: With the development of distributed generations (DGs), single-phase voltage source converter (SPVSC) has been widely used, but it brings about the problem of harmonic pollution to power grid. Hence, it is significant to explore the mechanism of harmonic injection from SPVSC and propose effective control strategies to mitigate the harmonic pollution. In this paper, a harmonic analysis model of SPVSC based on dynamic phasor (DP) has been established. With the model, the harmonics interaction between the ac side … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 23 publications
(31 reference statements)
0
3
0
Order By: Relevance
“…While tuning the circuit, a point is normally reached where further tuning does not produce any further improvement in THD. But with proper adjustments in the controller tuning process, however, it is possible to alter which harmonics are suppressed while maintaining the total harmonic distortion reasonably constant [3][4][5][6][7][8][9]. This is mainly because of the interaction between the dynamics of the controller and supply together with line inductance.…”
Section: Harmonics Of Inverter Circuitmentioning
confidence: 99%
“…While tuning the circuit, a point is normally reached where further tuning does not produce any further improvement in THD. But with proper adjustments in the controller tuning process, however, it is possible to alter which harmonics are suppressed while maintaining the total harmonic distortion reasonably constant [3][4][5][6][7][8][9]. This is mainly because of the interaction between the dynamics of the controller and supply together with line inductance.…”
Section: Harmonics Of Inverter Circuitmentioning
confidence: 99%
“…In recent years, with the intensification of the global energy crisis, the renewable energy and power electric technology have been integrated, which has promoted the development of distributed generators (DGs) [1,2]. e speed driver of small motor, voltage source converter, and a large number of nonlinear loads including electric arc furnace, high-power rectifier, transducer, and fluorescent are connected to the grid, which will cause harmonic pollution unavoidably [3][4][5].…”
Section: Introductionmentioning
confidence: 99%
“…e speed driver of small motor, voltage source converter, and a large number of nonlinear loads including electric arc furnace, high-power rectifier, transducer, and fluorescent are connected to the grid, which will cause harmonic pollution unavoidably [3][4][5]. e power grid operates in this state for a long run, which will bring great harm to power system and power consumers, mainly manifested in the following respects: (1) e line loss of the system is increasing greatly, and the operating efficiency of the grid is reduced. A lot of 3rd harmonics will also increase the neutral current, leading to the damage of the custom power devices.…”
Section: Introductionmentioning
confidence: 99%