2016
DOI: 10.1186/s12968-017-0323-0
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility of real-time MR thermal dose mapping for predicting radiofrequency ablation outcome in the myocardium in vivo

Abstract: BackgroundClinical treatment of cardiac arrhythmia by radiofrequency ablation (RFA) currently lacks quantitative and precise visualization of lesion formation in the myocardium during the procedure. This study aims at evaluating thermal dose (TD) imaging obtained from real-time magnetic resonance (MR) thermometry on the heart as a relevant indicator of the thermal lesion extent.MethodsMR temperature mapping based on the Proton Resonance Frequency Shift (PRFS) method was performed at 1.5 T on the heart, with 4 … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
49
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 52 publications
(52 citation statements)
references
References 37 publications
2
49
0
Order By: Relevance
“…Previously, we developed and validated a processing pipeline in a large animal model. 15,16 Here, we transferred this pipeline to a clinical environment and applied it to patients as a complement to a routine clinical MR scan. The raw data were streamed in real-time to a separate workstation and the images were reconstructed and processed online using the Gadgetron framework.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Previously, we developed and validated a processing pipeline in a large animal model. 15,16 Here, we transferred this pipeline to a clinical environment and applied it to patients as a complement to a routine clinical MR scan. The raw data were streamed in real-time to a separate workstation and the images were reconstructed and processed online using the Gadgetron framework.…”
Section: Discussionmentioning
confidence: 99%
“…Pacing of the heart during RFA may also help to improve the performance of thermometry, as suggested in a previous preclinical study. 16 Both retrospective strategies operate on different data streams and information. The G phase metric uses the phase image quality, while the arrhythmia rejection uses the RR interval duration.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In animal experiments, MRI has been shown to be able to predict histological lesion size and even identify gaps in ablation lines 16. If MRI is able to assess lesion quality in real-time, or can help predict lesion durability, for example, using thermography,17 it seems plausible that MR guidance can improve effectiveness of catheter ablation.…”
Section: Discussionmentioning
confidence: 99%
“…Small errors in registration mean that either a very broad region must be ablated or critical targets are left untouched, with consequent impact on safety, time and efficacy. [59][60][61] . The work of the Bordeaux group is particularly promising 61 , and implementation within a real-time interface appears to be feasible in the near future.…”
Section: Ep Substrate Identificationmentioning
confidence: 99%