2018
DOI: 10.1021/acs.analchem.8b01460
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility of Rare Earth Element Determination in Low Concentration in Crude Oil: Direct Sampling Electrothermal Vaporization-Inductively Coupled Plasma Mass Spectrometry

Abstract: A comprehensive study was developed showing the feasibility of determination of rare earth elements (REE) in low concentration in crude oil by using direct sampling electrothermal vaporization system coupled to inductively coupled plasma mass spectrometry (ETV-ICP-MS). The effect of organic modifier on the REE signal was evaluated and the use of 6 mg of citric acid allowed calibration using aqueous reference solutions (selected pyrolysis and vaporization temperatures were 700 and 2200 °C, respectively). Becaus… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 45 publications
(121 reference statements)
0
3
0
Order By: Relevance
“…This advantage related to the high sample throughput was also reported in other research studies involving the ETV-ICP-MS technique. 33,39,40 On using the reference method, determination by NEB-ICP-MS aer acid extraction, it was possible to make only four replicates per hour because the method has several steps which involve weighing, transferring the samples, and acid mixing in the vessels, and dilution with water, followed by centrifugation, since solid residues remained in the solution aer acid extraction, although the standing time (12 h) of the acid extraction procedure was not considered for the sample throughput estimation. Another important advantage of the ETV-ICP-MS method is the minimum sample manipulation, reducing the time of analysis.…”
Section: Analysis Of Bioresorbable Calcium Phosphate-based Materials ...mentioning
confidence: 99%
See 1 more Smart Citation
“…This advantage related to the high sample throughput was also reported in other research studies involving the ETV-ICP-MS technique. 33,39,40 On using the reference method, determination by NEB-ICP-MS aer acid extraction, it was possible to make only four replicates per hour because the method has several steps which involve weighing, transferring the samples, and acid mixing in the vessels, and dilution with water, followed by centrifugation, since solid residues remained in the solution aer acid extraction, although the standing time (12 h) of the acid extraction procedure was not considered for the sample throughput estimation. Another important advantage of the ETV-ICP-MS method is the minimum sample manipulation, reducing the time of analysis.…”
Section: Analysis Of Bioresorbable Calcium Phosphate-based Materials ...mentioning
confidence: 99%
“…22 To minimize analyte losses and memory effects, using a bypass gas (Ar) and establishing a proper heating program are essential. 22,33 However, sometimes it is difficult to overcome these limitations, making it unfeasible to use the system to analyze high-purity materials. The relatively high cost of acquisition and replacement materials is another negative aspect of this system for routine analysis.…”
Section: Introductionmentioning
confidence: 99%
“…The vapour is subsequently transported into the ICP by a carrier gas (Ar) through an inert tube. ETV-ICP-MS is specially well suited for the direct analysis of solids (0.1–5 mg) and slurries, 51 as well as for liquid samples (5 to 50 μL) such as oil or petroleum products, 52 because the organic matrix is easily removed. ETV-ICP-MS can offer lower detection limits and less risk of interferences as compared with sample nebulization.…”
Section: Overview Of Microsample Introduction Systems Into the Icpmentioning
confidence: 99%