Feasibility of Intravenous Administration of Landiolol Hydrochloride for Multislice Computed Tomography Coronary Angiography Initial Experience

Abstract: ultislice computed tomography (MSCT) coronary angiography (CAG) is emerging as a powerful noninvasive imaging strategy for the evaluation of atherosclerosis in patients with known or suspected coronary artery disease (CAD). 1-10 MSCT CAG not only assesses the degree of stenosis in the coronary lumen, but also provides direct information regarding the nonobstructive atherosclerotic plaque burden and plaque morphology within the vessel wall. 11,12 Despite technological advances, MSCT CAG has important limitation… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2012
2012
2014
2014

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 28 publications
(33 reference statements)
0
8
0
Order By: Relevance
“…Very few studies have reported the clinical use of the β 1 -receptor selective blocker landiolol hydrochloride [19, 20]. Isobe et al [19] reported the usefulness of the continuous injection of landiolol hydrochloride.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Very few studies have reported the clinical use of the β 1 -receptor selective blocker landiolol hydrochloride [19, 20]. Isobe et al [19] reported the usefulness of the continuous injection of landiolol hydrochloride.…”
Section: Discussionmentioning
confidence: 99%
“…Isobe et al [19] reported the usefulness of the continuous injection of landiolol hydrochloride. However, the continuous injection method is complicated.…”
Section: Discussionmentioning
confidence: 99%
“…0.75 mm, table feed of 3.0 mm/rotation, tube current of 400 mA, and tube voltage of 120 kV. 9 Measurements of oral fluid volume and renal function All patients were recommended to take as much oral fluid as possible. The amount of unrestricted oral fluid intake for 24 hours in each patient was calculated by nurses.…”
Section: Coronary Ctamentioning
confidence: 99%
“…Landiolol hydrochloride has been a useful agent for improving the image quality of CCTA by 64- and 320-slice multi-detector CT (MDCT) as it was confirmed to reduce heart rate significantly and rapidly after intravenous injection [9–11]. Although there are some studies in which the efficacy, safety, or usefulness of β-blockers has been explored [11, 12], no study has examined the usefulness and safety of short-acting β-blockers at an approved dosage and with approved administration in CCTA by 16-slice MDCT.…”
Section: Introductionmentioning
confidence: 99%
“…However, due to the cost of 64-slice CT, most small- and medium-sized hospitals still have 16-slice CT. Sixteen-row CT is less expensive than the newer CTs and is still widely used in Japan. In addition, new low-dose algorithms for the reduction of radiation exposure are also available in CCTA with 16-slice CT, and the X-ray exposure dose of 16-slice MDCT is less than that of the 64-slice MDCT [13, 14]. It is possible to obtain an appropriate coronary image by 16-slice MDCT [1522] if the patient’s heart rate during CCTA is properly controlled.…”
Section: Introductionmentioning
confidence: 99%