Feasibility of C 3 F 7 CN/CO 2 gas mixtures in high‐voltage DC GIL: a review on recent advances

Abstract: With the rise of renewable energy resources, especially offshore wind power plant, the DC transmission concept has attracted more and more attention. The selection of eco‐friendly insulating gas, as most critical insulating part of gas‐insulated equipment is top priority for developing highly reliable system. Moreover, it is acknowledged that eco‐friendly C3F7CN/CO2 gas mixtures have become a potential alternative to SF6 gas due to its excellent performance. This study reviews the basic physical properties of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
14
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 59 publications
0
14
0
Order By: Relevance
“…(2) SF 6 with N 2 or CF 4 gas mixtures [14,15]; (3) CF 3 I, c-C 4 F 8 with N 2 or CO 2 gas mixtures [16][17][18][19] [3,20]. From a long-term perspective, the use of SF 6 and its gas mixtures cannot fundamentally solve environmental issues, and the use of natural gases brings about the problem of mechanical and electrical structure redesign and manufacturing, together with a sharp rise in costs.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…(2) SF 6 with N 2 or CF 4 gas mixtures [14,15]; (3) CF 3 I, c-C 4 F 8 with N 2 or CO 2 gas mixtures [16][17][18][19] [3,20]. From a long-term perspective, the use of SF 6 and its gas mixtures cannot fundamentally solve environmental issues, and the use of natural gases brings about the problem of mechanical and electrical structure redesign and manufacturing, together with a sharp rise in costs.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, hundreds of eco-- 1 friendly alternative gases and their binary or multi-component mixtures have been studied internationally, among which CF 3 I, c-C 4 F 8 , C 5 F 10 O, C 6 F 12 O and C 4 F 7 N are considered to have good application prospects due to their excellent properties such as high insulation strength and low GWPs. C 4 F 7 N gas insulated 420kV GIL and 145 kV GIS, C 5 F 10 O gas insulated 22kV ring switch cabinet and C 6 F 12 O gas insulated C-GIS equipment have been developed [11][12][13][14][15][16][17][18][19][20].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…High voltage (HV) gas‐insulated transmission lines (GIL) is widely used in power plants and substations. Currently, more than 200 km of GIL are installed worldwide at voltage levels from 135 to 1100 kV [1, 2]. GIL has many advantages such as less occupied area, easy installation, high operational safety and high reliability.…”
Section: Introductionmentioning
confidence: 99%
“…The Gas-Insulated Transmission Line (GIL) has large transmission capacity, low environmental requirements, and meets the requirements of modern power systems, and has received more and more attention [1][2][3]. During the on-site installation process, due to the poor installation environment conditions, inadequate control of on-site installation and inspection and cleaning before capping was not strictly performed in accordance with process documents, impurities are likely to be brought in or left behind [4].…”
Section: Introductionmentioning